84566 | Rockwell Automation MicroLogix 1100 PLC Default Credentials | Nessus | SCADA | 7/7/2015 | 3/19/2024 | high |
87891 | Janitza Multiple UMG Devices Remote Debug Interface RCE | Nessus | SCADA | 1/13/2016 | 3/19/2024 | high |
89029 | 7-Technologies / Schneider-Electric IGSS ODBC Service Detection | Nessus | SCADA | 2/29/2016 | 3/19/2024 | info |
89030 | 7-Technologies IGSS < 9.0.0.11143 ODBC Invalid Structure RCE | Nessus | SCADA | 2/29/2016 | 3/19/2024 | critical |
57602 | Sensitive information can be obtained from the GE D20 Remote Terminal Unit via TFTP | Nessus | SCADA | 1/19/2012 | 3/19/2024 | high |
58991 | RuggedCom RuggedOS Default 'factory' Account Backdoor | Nessus | SCADA | 6/12/2012 | 3/19/2024 | critical |
72108 | Ecava IntegraXor < 4.1.4390 Buffer Overflow | Nessus | SCADA | 1/21/2014 | 3/19/2024 | high |
72486 | Cogent DataHub < 7.3.4 Malformed POST Request Buffer Overflow RCE | Nessus | SCADA | 2/13/2014 | 3/19/2024 | high |
91284 | Moxa NPort Serial-to-Ethernet Server Multiple Vulnerabilities | Nessus | SCADA | 5/20/2016 | 3/19/2024 | critical |
91384 | MicroLogix 1400 PLC Web Server Multiple Vulnerabilities | Nessus | SCADA | 5/31/2016 | 3/19/2024 | high |
53573 | Modbus/TCP Master OPC Server MODBUS Protocol Response Packet Remote Overflow | Nessus | SCADA | 4/27/2011 | 3/19/2024 | high |
127139 | 3S CODESYS V3 CmpUserMgr 3.x < 3.5.16.0 Password Transmission Vulnerability | Nessus | SCADA | 8/12/2019 | 4/23/2024 | high |
173829 | Delta Electronics InfraSuite Device Master Gateway Deserialization of Untrusted Data (CVE-2023-1133) | Nessus | SCADA | 4/4/2023 | 4/23/2024 | critical |
176666 | Moxa MXsecurity Series Detection | Nessus | SCADA | 6/5/2023 | 4/23/2024 | info |
183240 | LG LED Assistant Detection | Nessus | SCADA | 10/17/2023 | 4/23/2024 | info |
189747 | CyberPower PowerPanel Enterprise Detection | Nessus | SCADA | 1/29/2024 | 4/23/2024 | info |
103048 | Advantech WebAccess < 8.2_20170817 Multiple Vulnerabilities | Nessus | SCADA | 9/8/2017 | 4/23/2024 | critical |
112123 | Siemens Automation License Manager 5.x < 5.3.4.4 Multiple Vulnerabilities | Nessus | SCADA | 8/27/2018 | 4/23/2024 | high |
112124 | Siemens Automation License Manager 6.x < 6.0.1 Directory Traversal | Nessus | SCADA | 8/27/2018 | 4/23/2024 | high |
117360 | Advantech WebAccess webvrpcs.exe Path Traversal RCE | Nessus | SCADA | 9/10/2018 | 4/23/2024 | critical |
124329 | Advantech WebAccess webvrpcs.exe Arbitrary File Download | Nessus | SCADA | 4/26/2019 | 4/23/2024 | high |
131402 | Siemens SINEMA Remote Connect Server Multiple Vulnerabilities (SSA-884497) | Nessus | SCADA | 12/2/2019 | 4/23/2024 | critical |
146452 | Siemens TIA Administrator Detection | Nessus | SCADA | 2/12/2021 | 4/23/2024 | info |
23801 | Matrikon OPC Explorer Detection | Nessus | SCADA | 12/11/2006 | 4/23/2024 | info |
23804 | Siemens SIMATIC PDM Detection | Nessus | SCADA | 12/11/2006 | 4/23/2024 | info |
23967 | ICONICS Dialog Wrapper Module ActiveX (DlgWrapper.dll) DoModal Function Overflow | Nessus | SCADA | 1/3/2007 | 4/23/2024 | high |
52961 | 7-Technologies / Schneider-Electric IGSS Detection | Nessus | SCADA | 3/24/2011 | 4/23/2024 | info |
53572 | Automated Solutions Modbus/TCP OPC Server Detection | Nessus | SCADA | 4/27/2011 | 4/23/2024 | info |
56993 | Advantech / BroadWin WebAccess Client 'bwocxrun.ocx ' Multiple Remote Vulnerabilities | Nessus | SCADA | 12/2/2011 | 4/23/2024 | high |
58449 | 7-Technologies AQUIS Unspecified Path Subversion Arbitrary DLL Injection Code Execution | Nessus | SCADA | 3/23/2012 | 4/23/2024 | high |
58796 | Microsys PROMOTIC Detection | Nessus | SCADA | 4/19/2012 | 4/23/2024 | info |
59528 | RuggedCom RuggedOS Web-Based Admin Interface Default Credentials | Nessus | SCADA | 6/15/2012 | 4/23/2024 | critical |
63427 | Siemens Automation License Manager Detection | Nessus | SCADA | 1/9/2013 | 4/23/2024 | info |
66405 | Clorius Controls ISC SCADA Detection | Nessus | SCADA | 5/14/2013 | 4/23/2024 | info |
73517 | RuggedCom RuggedOS HTTP Traffic Handling Remote DoS | Nessus | SCADA | 4/15/2014 | 4/23/2024 | medium |
81545 | Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836) | Nessus | SCADA | 2/26/2015 | 4/23/2024 | medium |
81789 | Siemens SIMATIC STEP 7 (TIA Portal) Detection | Nessus | SCADA | 3/12/2015 | 4/23/2024 | info |
82665 | WellinTech KingView < 6.53 (2012-10-09) User Credentials Not Securely Hashed | Nessus | SCADA | 4/9/2015 | 4/23/2024 | low |
83187 | Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX Object Multiple Buffer Overflows DoS | Nessus | SCADA | 5/1/2015 | 4/23/2024 | high |
88414 | iniNet SpiderControl PLC Editor Simatic 6.30.04 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 4/23/2024 | high |
88415 | iniNet SpiderControl SCADA Editor 6.30.01 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 4/23/2024 | high |
97667 | Siemens SIMATIC Logon Detection | Nessus | SCADA | 3/10/2017 | 4/23/2024 | info |
73646 | Advantech WebAccess webvact ActiveX Multiple Buffer Overflow Vulnerabilities | Nessus | SCADA | 4/14/2014 | 4/23/2024 | high |
85411 | Advantech WebAccess < 7.2-2013.11.14 Multiple Vulnerabilities | Nessus | SCADA | 8/17/2015 | 4/23/2024 | high |
152099 | CODESYS V2 Web Server Detection | Nessus | SCADA | 7/27/2021 | 4/23/2024 | info |
47759 | Siemens SIMATIC WinCC Default Password Authentication Bypass | Nessus | SCADA | 7/16/2010 | 4/23/2024 | high |
51360 | Ecava IntegraXor ActiveX save Method Buffer Overflow | Nessus | SCADA | 12/22/2010 | 4/23/2024 | high |
59892 | WellinTech KingHistorian Detection | Nessus | SCADA | 7/6/2012 | 4/23/2024 | info |
62964 | IOServer Detection | Nessus | SCADA | 11/19/2012 | 4/23/2024 | info |
70591 | KEPServerEX Detection | Nessus | SCADA | 10/24/2013 | 4/23/2024 | info |