23826 | Modicon PLC Web Password Status Disclosure SNMP Request Password Status Remote Disclosure | Nessus | SCADA | 12/11/2006 | 3/19/2024 | medium |
57601 | SEL Controller Default Credentials | Nessus | SCADA | 1/19/2012 | 3/19/2024 | high |
58797 | Microsys PROMOTIC Project File Handling Use-after-free Remote Code Execution | Nessus | SCADA | 4/19/2012 | 3/19/2024 | high |
70559 | ClearSCADA Web Server Remote Denial of Service | Nessus | SCADA | 10/15/2013 | 3/19/2024 | high |
91623 | Cogent DataHub < 6.4.5Beta OPC Connection Failure DoS | Nessus | SCADA | 6/15/2016 | 3/19/2024 | medium |
87208 | 7-Technologies / Schneider-Electric IGSS Data Collector Detection | Nessus | SCADA | 12/4/2015 | 3/19/2024 | info |
94329 | OMRON FINS UDP Protocol Detection | Nessus | SCADA | 10/27/2016 | 3/19/2024 | info |
23817 | Modbus/TCP Coil Access | Nessus | SCADA | 12/11/2006 | 3/19/2024 | medium |
155947 | CODESYS V3 Web Server Heap-based Buffer Overflow (CVE-2021-33485) | Nessus | SCADA | 12/8/2021 | 3/19/2024 | critical |
131704 | 3S CODESYS CmpWebServerHandlerV3 Heap-based Buffer Overflow | Nessus | SCADA | 12/4/2019 | 4/23/2024 | critical |
149971 | Schneider Electric C-Gate < 2.11.6 Multiple Vulnerabilities | Nessus | SCADA | 5/26/2021 | 4/23/2024 | high |
152098 | CODESYS V2 Web Server Improperly Implemented Security Check (2021-07) | Nessus | SCADA | 7/27/2021 | 4/23/2024 | critical |
176665 | Moxa MXsecurity Series Hard-coded JWT Key Authentication Bypass (CVE-2023-33236) | Nessus | SCADA | 6/5/2023 | 4/23/2024 | critical |
76574 | Triangle MicroWorks SCADA Data Gateway < 3.0.635 Multiple DoS Vulnerabilities | Nessus | SCADA | 7/17/2014 | 4/23/2024 | medium |
77964 | Ecava IntegraXor < 4.2.4458 Multiple Vulnerabilities | Nessus | SCADA | 9/29/2014 | 4/23/2024 | high |
81249 | MatrikonOPC Server for DNP3 < 1.2.3.1 Message Handling Remote DoS | Nessus | SCADA | 2/9/2015 | 4/23/2024 | medium |
81700 | Advantech ADAMView Multiple Buffer Overflow Vulnerabilities | Nessus | SCADA | 3/9/2015 | 4/23/2024 | high |
82664 | SCADA Engine BACnet OPC Server < 2.1.371.24 Multiple Vulnerabilities | Nessus | SCADA | 4/9/2015 | 4/23/2024 | high |
84262 | Schneider Electric InduSoft Web Studio Detection | Nessus | SCADA | 6/18/2015 | 4/23/2024 | info |
85692 | Advantech WebAccess < 7.0-2011.12.20 Multiple Vulnerabilities | Nessus | SCADA | 8/28/2015 | 4/23/2024 | high |
86899 | Advantech WebAccess < 8.0.2015.08.16 Unspecified DLL String Handling Arbitrary Code Execution | Nessus | SCADA | 11/17/2015 | 4/23/2024 | medium |
88416 | iniNet SpiderControl SCADA Web Server 2.02 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 4/23/2024 | high |
89111 | Advantech WebAccess < 8.1-2015.12.30 Multiple Vulnerabilities | Nessus | SCADA | 3/3/2016 | 4/23/2024 | high |
96876 | Advantech WebAccess SQLi | Nessus | SCADA | 1/30/2017 | 4/23/2024 | critical |
136182 | 3S CODESYS Runtime 3.x < 3.5.15.40 Multiple Vulnerabilities | Nessus | SCADA | 4/30/2020 | 4/23/2024 | critical |
172391 | Contec CONPROSYS HMI System (CHS) OS Command Injection (CVE-2022-44456) | Nessus | SCADA | 3/9/2023 | 4/23/2024 | critical |
172392 | Contec CONPROSYS HMI System (CHS) Detection | Nessus | SCADA | 3/9/2023 | 4/23/2024 | info |
174122 | Contec CONPROSYS HMI System (CHS) SQL Injection (CVE-2023-1658) | Nessus | SCADA | 4/11/2023 | 4/23/2024 | high |
183239 | LG LED Assistant Path Traversal (CVE-2023-4613) | Nessus | SCADA | 10/17/2023 | 4/23/2024 | critical |
155154 | Nucleus FTP Server Multiple Vulnerabilities (NUCLEUS:13) | Nessus | SCADA | 11/11/2021 | 3/19/2024 | critical |
192106 | Milesight MilesightVPN Detection | Nessus | SCADA | 3/14/2024 | 4/23/2024 | info |
192107 | Milesight MilesightVPN Authentication Bypass (CVE-2023-22844) | Nessus | SCADA | 3/14/2024 | 4/23/2024 | critical |
66406 | Clorius Controls ISC SCADA Information Disclosure | Nessus | SCADA | 5/14/2013 | 4/23/2024 | medium |
70351 | RuggedCom RuggedOS < 3.12.2 Multiple Vulnerabilities | Nessus | SCADA | 10/7/2013 | 4/23/2024 | high |
90002 | PACTware 4.1 SP3 (4.1.0.42) File Processing Error Handling DoS | Nessus | SCADA | 3/17/2016 | 4/23/2024 | medium |
135696 | Rockwell Automation RSLinx Classic < 4.11.00 Local Privilege Escalation | Nessus | SCADA | 4/17/2020 | 4/23/2024 | high |
81299 | Siemens SIMATIC TIA Portal 13.x < 13 Upd6 Remote Code Execution | Nessus | SCADA | 2/11/2015 | 4/23/2024 | critical |
82853 | Siemens SIMATIC WinCC (TIA Portal) 13.x < 13 SP1 Upd2 Multiple Vulnerabilities (SSA-487246) | Nessus | SCADA | 4/17/2015 | 4/23/2024 | high |
189258 | Rockwell FactoryTalk Services Platform 2.74 Authentication Bypass | Nessus | SCADA | 1/20/2024 | 1/22/2024 | high |
170033 | Schneider Electric APC Easy UPS Online Monitoring Software Missing Authentication (CVE-2022-42970) | Nessus | SCADA | 1/13/2023 | 4/23/2024 | critical |
50687 | RealWin < 2.1.10 Multiple Packet Type Processing Overflows | Nessus | SCADA | 11/23/2010 | 3/19/2024 | critical |
162819 | Keysight Technologies Sensor Management Server Deserialization RCE (CVE-2022-1660) | Nessus | SCADA | 7/7/2022 | 4/23/2024 | critical |
58448 | 7-Technologies AQUIS Detection | Nessus | SCADA | 3/23/2012 | 4/29/2024 | info |
59375 | WellinTech KingView 6.53 < 2010-12-15 HistorySvr.exe TCP Request Remote Overflow | Nessus | SCADA | 6/5/2012 | 4/29/2024 | critical |
109145 | Schneider Electric InTouch Machine Edition Detection | Nessus | SCADA | 4/18/2018 | 4/29/2024 | info |
109146 | Schneider Electric InduSoft Web Studio Detection | Nessus | SCADA | 4/18/2018 | 4/29/2024 | info |
189287 | Rockwell FactoryTalk Activation Manager Installed (Windows) | Nessus | SCADA | 1/22/2024 | 4/29/2024 | info |
23815 | SISCO OSI/ICCP Stack Detection | Nessus | SCADA | 12/11/2006 | 4/29/2024 | info |
26066 | Automated Solutions Modbus Slave MiniHMI.exe ActiveX Modbus/TCP Diagnostic Function Arbitrary Code Execution | Nessus | SCADA | 9/19/2007 | 4/29/2024 | high |
55630 | Sielco Sistemi Winlog Detection | Nessus | SCADA | 7/19/2011 | 4/29/2024 | info |