| 151190 | Johnson Controls exacqVision Web Service Detection | Nessus | SCADA | 6/30/2021 | 10/29/2026 | info |
| 152098 | CODESYS V2 Web Server Improperly Implemented Security Check (2021-07) | Nessus | SCADA | 7/27/2021 | 10/29/2026 | critical |
| 164195 | Advantech iView runProViewUpgrade fwfilename Command Injection (CVE-2022-2143) | Nessus | SCADA | 8/17/2022 | 10/29/2026 | critical |
| 164696 | Keysight Technologies Sensor Management Server addLicenseFile Path Traversal (CVE-2022-38129) | Nessus | SCADA | 9/6/2022 | 10/29/2026 | critical |
| 182187 | Control iD iDSecure Detection | Nessus | SCADA | 9/29/2023 | 10/29/2026 | info |
| 182188 | Control iD iDSecure Hard-coded JWT Key Authentication Bypass (CVE-2023-33371) | Nessus | SCADA | 9/29/2023 | 10/29/2026 | critical |
| 183239 | LG LED Assistant Path Traversal (CVE-2023-4613) | Nessus | SCADA | 10/17/2023 | 10/29/2026 | critical |
| 183240 | LG LED Assistant Detection | Nessus | SCADA | 10/17/2023 | 10/29/2026 | info |
| 192106 | Milesight MilesightVPN Detection | Nessus | SCADA | 3/14/2024 | 10/29/2026 | info |
| 234854 | Rockwell Automation FactoryTalk Updater Authentication Bypass (CVE-2024-10943 | Nessus | SCADA | 4/25/2025 | 10/29/2026 | critical |
| 235084 | GMOD Apollo Detection | Nessus | SCADA | 5/2/2025 | 10/29/2026 | info |
| 23820 | Modicon PLC Embedded HTTP Server Detection | Nessus | SCADA | 12/11/2006 | 10/29/2026 | medium |
| 23822 | Modicon Quantum HTTP Server Default Credentials | Nessus | SCADA | 12/11/2006 | 10/29/2026 | high |
| 241649 | mySCADA PRO Manager Missing Authentication (CVE-2025-24865) | Nessus | SCADA | 7/9/2025 | 10/29/2026 | critical |
| 58991 | RuggedCom RuggedOS Default 'factory' Account Backdoor | Nessus | SCADA | 6/12/2012 | 10/29/2026 | critical |
| 64487 | RuggedCom RuggedOS < 3.12.1 Web UI Multiple Security Vulnerabilities | Nessus | SCADA | 2/6/2013 | 10/29/2026 | critical |
| 67143 | Tridium Niagara AX Web Server Directory Traversal 'config.bog' Disclosure Remote Compromise | Nessus | SCADA | 7/3/2013 | 10/29/2026 | high |
| 73642 | Advantech WebAccess Stored Cross-Site Scripting | Nessus | SCADA | 4/14/2014 | 10/29/2026 | low |
| 80359 | StruxureWare SCADA Expert ClearSCADA Remote Security Bypass | Nessus | SCADA | 1/5/2015 | 10/29/2026 | medium |
| 85543 | Advantech WebAccess < 7.0-2011.08.27 Multiple ActiveX RCE | Nessus | SCADA | 8/19/2015 | 10/29/2026 | medium |
| 87125 | Emerson SM-Ethernet Web Interface Default Credentials | Nessus | SCADA | 12/1/2015 | 10/29/2026 | high |
| 88414 | iniNet SpiderControl PLC Editor Simatic 6.30.04 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 10/29/2026 | high |
| 88416 | iniNet SpiderControl SCADA Web Server 2.02 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 10/29/2026 | high |
| 90599 | Rockwell Automation MicroLogix 1400 PLC Default Credentials | Nessus | SCADA | 4/20/2016 | 10/29/2026 | critical |
| 96875 | Advantech WebAccess Authentication Bypass | Nessus | SCADA | 1/30/2017 | 10/29/2026 | critical |
| 158459 | VISAM Automation Base (VBASE) Web-Remote Path Traversal (CVE-2020-7008) | Nessus | SCADA | 3/1/2022 | 10/29/2026 | high |
| 125312 | Rockwell Automation MicroLogix 1100/1400 and CompactLogix 5370 Controllers Open Redirection Vulnerability | Nessus | SCADA | 5/21/2019 | 10/29/2026 | medium |
| 131704 | 3S CODESYS CmpWebServerHandlerV3 Heap-based Buffer Overflow | Nessus | SCADA | 12/4/2019 | 9/10/2026 | critical |
| 127139 | 3S CODESYS V3 CmpUserMgr 3.x < 3.5.16.0 Password Transmission Vulnerability | Nessus | SCADA | 8/12/2019 | 9/10/2026 | high |
| 155947 | CODESYS V3 Web Server Heap-based Buffer Overflow (CVE-2021-33485) | Nessus | SCADA | 12/8/2021 | 10/29/2026 | critical |
| 373882 | Johnson Controls victor Application Server Deserialization RCE (CVE-2026-21655) | Nessus | SCADA | 10/29/2026 | 11/2/2026 | high |
| 101930 | Fuji Electric V-Server Detection | Nessus | SCADA | 7/24/2017 | 9/29/2025 | info |
| 130431 | CODESYS Gateway V3 Detection | Nessus | SCADA | 10/31/2019 | 9/29/2025 | info |
| 149308 | CodeMeter Runtime Detection | Nessus | SCADA | 5/6/2021 | 9/29/2025 | info |
| 149972 | Schneider Electric C-Gate Detection | Nessus | SCADA | 5/26/2021 | 7/14/2025 | info |
| 23809 | DNP3 Binary Inputs Access Remote Information Disclosure | Nessus | SCADA | 12/11/2006 | 9/29/2025 | medium |
| 23812 | ICCP/COTP TSAP Addressing Weakness | Nessus | SCADA | 12/11/2006 | 9/29/2025 | medium |
| 23827 | Modicon Quantum Telnet Server Default Credentials | Nessus | SCADA | 12/11/2006 | 7/14/2025 | medium |
| 33169 | CitectSCADA Detection | Nessus | SCADA | 6/13/2008 | 5/24/2023 | info |
| 57601 | SEL Controller Default Credentials | Nessus | SCADA | 1/19/2012 | 7/14/2025 | high |
| 57602 | Sensitive information can be obtained from the GE D20 Remote Terminal Unit via TFTP | Nessus | SCADA | 1/19/2012 | 9/29/2025 | high |
| 81591 | Siemens SIMATIC S7-1200 PLC Firmware Detection | Nessus | SCADA | 3/2/2015 | 7/14/2025 | info |
| 83302 | Modbus/TCP Report Slave ID | Nessus | SCADA | 5/10/2015 | 9/29/2025 | medium |
| 91283 | Moxa NPort Serial-to-Ethernet Server Detection | Nessus | SCADA | 5/20/2016 | 7/14/2025 | info |
| 91622 | Cogent DataHub < 6.4.3 OPC Client Reconnection Saturation Remote DoS | Nessus | SCADA | 6/15/2016 | 7/14/2025 | medium |
| 23819 | Modicon Modbus/TCP Programming Function Code Access | Nessus | SCADA | 12/11/2006 | 7/14/2025 | medium |
| 83467 | EtherNet/IP CIP List of Active Object Classes | Nessus | SCADA | 5/14/2015 | 9/29/2025 | info |
| 94329 | OMRON FINS UDP Protocol Detection | Nessus | SCADA | 10/27/2016 | 7/17/2026 | info |
| 173823 | Rockwell Automation ThinManager ThinServer Detection | Nessus | SCADA | 4/4/2023 | 9/10/2026 | info |
| 177892 | Rockwell Automation ControlLogix Service Detection | Nessus | SCADA | 7/3/2023 | 9/10/2026 | info |