Siemens (CVE-2019-6585)

medium Tenable OT Security Plugin ID 500899

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf

https://www.us-cert.gov/ics/advisories/icsa-20-042-10

Plugin Details

Severity: Medium

ID: 500899

File Name: tenable_ot_siemens_CVE-2019-6585.nasl

Version: 1.7

Type: Remote

Family: Tenable.ot

Published: 3/27/2023

Updated: 6/19/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.0

CVSS v2

Risk Factor: Medium

Base Score: 4.3

Vector: CVSS2#AV:N/AC:M/Au:N/C:N/I:P/A:N

CVSS Score Source: CVE-2019-6585

CVSS v3

Risk Factor: Medium

Base Score: 6.1

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Vulnerability Information

CPE: cpe:/o:siemens:scalance_s627-2m_firmware, cpe:/o:siemens:scalance_s602_firmware, cpe:/o:siemens:scalance_s623_firmware, cpe:/o:siemens:scalance_s612_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 3/10/2020

Vulnerability Publication Date: 3/10/2020

Reference Information

CVE: CVE-2019-6585

CWE: 79, 80

ICSA: 20-042-10