An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.

References

https://www.tenable.com/security/research/tra-2020-71

Details

Source: MITRE

Published: 2020-12-29

Updated: 2020-12-30

Type: CWE-755

Risk Information

CVSS v2

Base Score: 5

Vector: AV:N/AC:L/Au:N/C:N/I:N/A:P

Impact Score: 2.9

Exploitability Score: 10

Severity: MEDIUM

CVSS v3

Base Score: 7.5

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Impact Score: 3.6

Exploitability Score: 3.9

Severity: HIGH