800-53|SI-4

Title

INFORMATION SYSTEM MONITORING

Description

The organization:

Supplemental

Information system monitoring includes external and internal monitoring. External monitoring includes the observation of events occurring at the information system boundary (i.e., part of perimeter defense and boundary protection). Internal monitoring includes the observation of events occurring within the information system. Organizations can monitor information systems, for example, by observing audit activities in real time or by observing other system aspects such as access patterns, characteristics of access, and other actions. The monitoring objectives may guide determination of the events. Information system monitoring capability is achieved through a variety of tools and techniques (e.g., intrusion detection systems, intrusion prevention systems, malicious code protection software, scanning tools, audit record monitoring software, network monitoring software). Strategic locations for monitoring devices include, for example, selected perimeter locations and near server farms supporting critical applications, with such devices typically being employed at the managed interfaces associated with controls SC-7 and AC-17. Einstein network monitoring devices from the Department of Homeland Security can also be included as monitoring devices. The granularity of monitoring information collected is based on organizational monitoring objectives and the capability of information systems to support such objectives. Specific types of transactions of interest include, for example, Hyper Text Transfer Protocol (HTTP) traffic that bypasses HTTP proxies. Information system monitoring is an integral part of organizational continuous monitoring and incident response programs. Output from system monitoring serves as input to continuous monitoring and incident response programs. A network connection is any connection with a device that communicates through a network (e.g., local area network, Internet). A remote connection is any connection with a device communicating through an external network (e.g., the Internet). Local, network, and remote connections can be either wired or wireless.

Reference Item Details

Related: AC-17,AC-3,AC-4,AC-8,AU-12,AU-2,AU-6,AU-7,AU-9,CA-7,IR-4,PE-3,RA-5,SC-26,SC-35,SC-7,SI-3,SI-7

Category: SYSTEM AND INFORMATION INTEGRITY

Family: SYSTEM AND INFORMATION INTEGRITY

Priority: P1

Baseline Impact: LOW,MODERATE,HIGH

Audit Items

View all Reference Audit Items

NamePluginAudit Name
1.1 Ensure the Pre-Installation Planning Checklist Has Been ImplementedUnixCIS Apache HTTP Server 2.4 L1 v2.1.0 Middleware
1.1 Ensure the Pre-Installation Planning Checklist Has Been ImplementedUnixCIS Apache HTTP Server 2.4 L1 v2.1.0
1.1.3.9.12 Configure 'MSS: (NoNameReleaseOnDemand) Allow the computer to ignore NetBIOS name release requests except from WINS servers'WindowsCIS Windows 8 L1 v1.0.0
1.1.3.11.10 Set 'Network Security: Restrict NTLM: Audit Incoming NTLM Traffic' to 'Not Defined'WindowsCIS Windows 8 L1 v1.0.0
1.1.3.16.1 Configure 'System settings: Optional subsystems'WindowsCIS Windows 8 L1 v1.0.0
1.1.5 Ensure that the --insecure-bind-address argument is not setUnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.1.6 Ensure that the --insecure-port argument is set to 0UnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.1.19 Ensure that the --authorization-mode argument is not set to AlwaysAllowUnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.1.32 Ensure that the --authorization-mode argument includes NodeUnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.1.39 Ensure that the --authorization-mode argument includes RBACUnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.2 Disable Unused ConnectorsUnixCIS Apache Tomcat 8 L2 v1.1.0
1.2 Disable Unused ConnectorsUnixCIS Apache Tomcat 8 L2 v1.1.0 Middleware
1.2.2 Ensure that the --address argument is set to 127.0.0.1UnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.2.3 Set 'no exec' for 'line aux 0'CiscoCIS Cisco IOS 15 L1 v4.1.1
1.2.4 Disable the rhnsd DaemonUnixCIS Red Hat Enterprise Linux 5 L2 v2.2.1
1.2.4 Ensure HTTP and Telnet options are disabled for all management profiles - HTTPPalo_AltoCIS Palo Alto Firewall 8 Benchmark L1 v1.0.0
1.2.4 Ensure HTTP and Telnet options are disabled for all management profiles - TelnetPalo_AltoCIS Palo Alto Firewall 8 Benchmark L1 v1.0.0
1.2.5 Disable the rhnsd DaemonUnixCIS Red Hat 6 Server L2 v3.0.0
1.2.5 Disable the rhnsd DaemonUnixCIS Red Hat 6 Workstation L2 v3.0.0
1.2.5 Disable yum-updatesdUnixCIS Red Hat Enterprise Linux 5 L2 v2.2.1
1.2.6 Obtain Software Package Updates with yumUnixCIS Red Hat Enterprise Linux 5 L1 v2.2.1
1.3.7 Ensure that the --address argument is set to 127.0.0.1UnixCIS Kubernetes 1.13 Benchmark v1.4.1 L1
1.3.10 Ensure 'Password Profiles' do not existPalo_AltoCIS Palo Alto Firewall 10 v1.1.0 L1
1.4.4 Remove SETroubleshootUnixCIS Red Hat Enterprise Linux 5 L2 v2.2.1
1.4.5 Disable MCS Translation Service (mcstrans)UnixCIS Red Hat Enterprise Linux 5 L2 v2.2.1
1.4.6 Check for Unconfined DaemonsUnixCIS Red Hat Enterprise Linux 5 L2 v2.2.1
1.4.6 Do not Configure a Read Write SNMP Community StringCiscoCIS Cisco NX-OS L1 v1.0.0
1.4.6 Do not Configure a Read Write SNMP Community StringCiscoCIS Cisco NX-OS L2 v1.0.0
1.5.1 Ensure 'V3' is selected for SNMP pollingPalo_AltoCIS Palo Alto Firewall 8 Benchmark L1 v1.0.0
1.5.1 Set 'no snmp-server' to disable SNMP when unusedCiscoCIS Cisco IOS 12 L1 v4.0.0
1.5.4 Do not set 'RW' for any 'snmp-server community'CiscoCIS Cisco IOS 12 L1 v4.0.0
1.6.1.6 Ensure no unconfined daemons existUnixCIS CentOS 6 Workstation L1 v3.0.0
1.6.1.6 Ensure no unconfined daemons existUnixCIS Oracle Linux 6 Server L1 v2.0.0
1.6.1.6 Ensure no unconfined daemons existUnixCIS Oracle Linux 6 Workstation L1 v2.0.0
1.6.1.6 Ensure no unconfined daemons existUnixCIS Red Hat 6 Server L1 v3.0.0
1.6.1.6 Ensure no unconfined daemons existUnixCIS CentOS 6 Server L1 v3.0.0
1.6.1.6 Ensure no unconfined daemons existUnixCIS Red Hat 6 Workstation L1 v3.0.0
1.6.1.8 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS Oracle Linux 6 Workstation L1 v2.0.0
1.6.1.8 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS Red Hat 6 Server L1 v3.0.0
1.6.1.8 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS Red Hat 6 Workstation L1 v3.0.0
1.6.1.8 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS CentOS 6 Workstation L1 v3.0.0
1.6.1.8 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS Oracle Linux 6 Server L1 v2.0.0
1.6.1.8 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS CentOS 6 Server L1 v3.0.0
1.6.2.5 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS Distribution Independent Linux Workstation L2 v2.0.0
1.6.2.5 Ensure the MCS Translation Service (mcstrans) is not installedUnixCIS Distribution Independent Linux Server L2 v2.0.0
1.6.2.6 Ensure no unconfined daemons existUnixCIS Distribution Independent Linux Server L2 v2.0.0
1.6.2.6 Ensure no unconfined daemons existUnixCIS Distribution Independent Linux Workstation L2 v2.0.0
1.12 Ensure host-based intrusion detection tool is used - mcafeetp packageUnixCIS Red Hat Enterprise Linux 7 STIG v2.0.0 STIG
1.12 Ensure host-based intrusion detection tool is used - mfetpd processUnixCIS Red Hat Enterprise Linux 7 STIG v2.0.0 STIG
1.15 Ensure all Public Web Tier SSL\TLS certificates are >30 days from Expirationamazon_awsCIS Amazon Web Services Three-tier Web Architecture L2 1.0.0