| 500535 | Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC Weak Password Recovery Mechanism For Forgotten Password (CVE-2021-22763) | Tenable OT Security | Tenable.ot | 12/18/2024 | critical |
| 500534 | Mitsubishi Electric SmartRTU Forced Browsing (CVE-2018-16060) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500518 | Mitsubishi Electric SmartRTU Cross-site Scripting (CVE-2018-16061) | Tenable OT Security | Tenable.ot | 12/18/2024 | medium |
| 500312 | Mitsubishi Electric MELSEC-Q QJ71E71 series Use of a Broken or Risky Cryptographic Algorithm (CVE-2016-8370) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500258 | Rockwell Automation ControlLogix Cross-site Scripting (CVE-2009-0472) | Tenable OT Security | Tenable.ot | 12/18/2024 | medium |
| 500254 | Rockwell Automation Controllers Denial Of Service (CVE-2012-6439) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500253 | Rockwell Automation ControlLogix controllers Improper Authentication (CVE-2012-6437) | Tenable OT Security | Tenable.ot | 12/18/2024 | critical |
| 500241 | Mitsubishi Electric MELSEC-Q QJ71E71 series Improper Synchronization (CVE-2016-8368) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500198 | Rockwell Automation ControlLogix controllers Resource Management Errors (CVE-2012-6435) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500190 | Rockwell Automation MicroLogix Resource Management Errors (CVE-2014-5410) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500183 | Rockwell Automation ControlLogix Link Following (CVE-2009-0473) | Tenable OT Security | Tenable.ot | 12/18/2024 | medium |
| 500147 | Rockwell Automation ControlLogix controllers Exposure of Sensitive Information to an Unauthorized Actor (CVE-2012-6441) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500133 | Rockwell Automation ControlLogix controllers Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2012-6438) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500111 | Rockwell Automation ControlLogix controllers Improper Authentication (CVE-2012-6440) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500076 | Rockwell Automation Micrologix Privilege escalation and Denial of Service (CVE-2009-3739) | Tenable OT Security | Tenable.ot | 12/18/2024 | critical |
| 500044 | Rockwell Automation RSLogix Improper Access Control (CVE-2010-5305) | Tenable OT Security | Tenable.ot | 12/18/2024 | critical |
| 500042 | Rockwell Automation 1756 Incorrect Authorization (CVE-2010-2965) | Tenable OT Security | Tenable.ot | 12/18/2024 | critical |
| 500036 | Rockwell Automation ControlLogix controllers Buffer Overflow (CVE-2012-6436) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500031 | Rockwell Automation ControlLogix Exposure of Sensitive Information to an Unauthorized Actor (CVE-2009-0474) | Tenable OT Security | Tenable.ot | 12/18/2024 | medium |
| 500028 | Rockwell Automation Logix Controllers Denial of Service (CVE-2012-6442) | Tenable OT Security | Tenable.ot | 12/18/2024 | high |
| 500012 | Rockwell Automation Controller Asset Information | Tenable OT Security | Tenable.ot | 12/18/2024 | info |
| 502689 | Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2024-8933) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502688 | Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Authentication Bypass By Spoofing (CVE-2024-8935) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502684 | Mitsubishi Electric MELSEC iQ-F Series Improper Validation of Specified Type of Input (CVE-2024-8403) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502663 | Siemens SIMATIC CP Incorrect Authorization (CVE-2024-50310) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502662 | Siemens SCALANCE M-800 Family Improper Access Control (CVE-2024-50558) | Tenable OT Security | Tenable.ot | 12/12/2024 | medium |
| 502659 | Siemens SCALANCE M-800 Family Improper Input Validation (CVE-2024-50557) | Tenable OT Security | Tenable.ot | 12/12/2024 | critical |
| 502658 | Siemens SCALANCE M-800 Family Improper Limitation of a Pathname to a Restricted Directory (CVE-2024-50559) | Tenable OT Security | Tenable.ot | 12/12/2024 | medium |
| 502654 | Rockwell Automation Logix Controllers Uncontrolled Resource Consumption (CVE-2024-8626) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502652 | Siemens SIMATIC S7-1500 CPUs Authentication Bypass Using an Alternate Path or Channel (CVE-2024-46887) | Tenable OT Security | Tenable.ot | 12/12/2024 | medium |
| 502648 | Rockwell Automation ControlLogix Improper Input Validation (CVE-2024-6207) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502482 | Siemens SIMATIC S7-200 SMART Devices Uncontrolled Resource Consumption (CVE-2024-43647) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502367 | Siemens SCALANCE M-800, RUGGEDCOM RM1224 Improper Input Validation (CVE-2024-41976) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502366 | Siemens SCALANCE M-800, RUGGEDCOM RM1224 Exposure of Data Element to Wrong Session (CVE-2024-41977) | Tenable OT Security | Tenable.ot | 12/12/2024 | high |
| 502365 | Siemens SCALANCE M-800, RUGGEDCOM RM1224 Insertion of Sensitive Information Into Log File (CVE-2024-41978) | Tenable OT Security | Tenable.ot | 12/12/2024 | medium |
| 501870 | Siemens SCALANCE M-800, RUGGEDCOM RM1224 Uncontrolled Resource Consumption (CVE-2023-44321) | Tenable OT Security | Tenable.ot | 12/12/2024 | medium |
| 501142 | Siemens SIPROTEC 5 Devices Null Pointer Dereference (CVE-2023-28766) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 501140 | Siemens RADIUS Client of SIPROTEC 5 Devices Loop with Unreachable Exit Condition (CVE-2022-38767) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500874 | Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-11451) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500692 | Siemens EN100 Ethernet Module Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2022-30938) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500660 | Siemens EN100 Ethernet Module Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2022-30937) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500354 | Siemens EN100 Ethernet Module Relative Path Traversal (CVE-2019-13944) | Tenable OT Security | Tenable.ot | 12/9/2024 | medium |
| 500353 | Siemens EN100 Ethernet Module Improper Neutralization of Input During Web Page Generation (CVE-2019-13943) | Tenable OT Security | Tenable.ot | 12/9/2024 | medium |
| 500352 | Siemens EN100 Ethernet Module Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2019-13942) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500280 | Siemens Siprotec5 Improper Access Control (CVE-2019-10938) | Tenable OT Security | Tenable.ot | 12/9/2024 | critical |
| 500202 | Siemens SIPROTEC 5 and DIGSI 5 Improper Input Validation (CVE-2019-10931) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500163 | Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension Missing Authentication For Critical Function (CVE-2018-4838) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500119 | Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Missing Authentication For Critical Function (CVE-2018-4840) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 500050 | Siemens SIPROTEC 5 and DIGSI 5 Improper Input Validation (CVE-2019-10930) | Tenable OT Security | Tenable.ot | 12/9/2024 | high |
| 502801 | Cisco NX-OS Fibre Channel over Ethernet Denial of Service (CVE-2017-6655) | Tenable OT Security | Tenable.ot | 12/5/2024 | medium |