Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-31698)

high Tenable OT Security Plugin ID 506430

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

crypto: ccp: Don't attempt to copy PDH cert to userspace if PSP command failed

When retrieving the PDH cert, don't attempt to copy the blobs to userspace if the firmware command failed. If the failure was due to an invalid length, i.e. the userspace buffer+length was too small, copying the number of bytes _firmware_ requires will overflow the kernel-allocated buffer and leak data to userspace.

BUG: KASAN: slab-out-of-bounds in instrument_copy_to_user ../include/linux/instrumented.h:129 [inline] BUG: KASAN: slab-out-of-bounds in _inline_copy_to_user ../include/linux/uaccess.h:205 [inline] BUG: KASAN: slab-out-of-bounds in _copy_to_user+0x66/0xa0 ../lib/usercopy.c:26 Read of size 2084 at addr ffff8885c4ab8aa0 by task syz.0.186/21033

CPU: 51 UID: 0 PID: 21033 Comm: syz.0.186 Tainted: G U O 7.0.0-smp-DEV #28 PREEMPTLAZY Tainted: [U]=USER, [O]=OOT_MODULE Hardware name: Google, Inc. Arcadia_IT_80/Arcadia_IT_80, BIOS 34.84.12-0 11/17/2025 Call Trace:
<TASK> dump_stack_lvl+0xc5/0x110 ../lib/dump_stack.c:120 print_address_description ../mm/kasan/report.c:378 [inline] print_report+0xbc/0x260 ../mm/kasan/report.c:482 kasan_report+0xa2/0xe0 ../mm/kasan/report.c:595 check_region_inline ../mm/kasan/generic.c:-1 [inline] kasan_check_range+0x264/0x2c0 ../mm/kasan/generic.c:200 instrument_copy_to_user ../include/linux/instrumented.h:129 [inline]
_inline_copy_to_user ../include/linux/uaccess.h:205 [inline]
_copy_to_user+0x66/0xa0 ../lib/usercopy.c:26 copy_to_user ../include/linux/uaccess.h:236 [inline] sev_ioctl_do_pdh_export+0x3d3/0x7c0 ../drivers/crypto/ccp/sev-dev.c:2347 sev_ioctl+0x2a2/0x490 ../drivers/crypto/ccp/sev-dev.c:2568 vfs_ioctl ../fs/ioctl.c:51 [inline]
__do_sys_ioctl ../fs/ioctl.c:597 [inline]
__se_sys_ioctl+0x11d/0x1b0 ../fs/ioctl.c:583 do_syscall_x64 ../arch/x86/entry/syscall_64.c:63 [inline] do_syscall_64+0xe0/0x800 ../arch/x86/entry/syscall_64.c:94 entry_SYSCALL_64_after_hwframe+0x76/0x7e </TASK>

WARN if the driver says the command succeeded, but the firmware error code says otherwise, as __sev_do_cmd_locked() is expected to return -EIO on any firwmware error.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506430

File Name: tenable_ot_siemens_CVE-2026-31698.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.3

Percentile: 53.63

CVSS v3

Risk Factor: High

Base Score: 7.1

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-31698

CWE: 20