Siemens SIMATIC S7-1500 TM MFP Use After Free (CVE-2025-39863)

high Tenable OT Security Plugin ID 506412

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

wifi: brcmfmac: fix use-after-free when rescheduling brcmf_btcoex_info work

The brcmf_btcoex_detach() only shuts down the btcoex timer, if the flag timer_on is false. However, the brcmf_btcoex_timerfunc(), which runs as timer handler, sets timer_on to false. This creates critical race conditions:

1.If brcmf_btcoex_detach() is called while brcmf_btcoex_timerfunc() is executing, it may observe timer_on as false and skip the call to timer_shutdown_sync().

2.The brcmf_btcoex_timerfunc() may then reschedule the brcmf_btcoex_info worker after the cancel_work_sync() has been executed, resulting in use-after-free bugs.

The use-after-free bugs occur in two distinct scenarios, depending on the timing of when the brcmf_btcoex_info struct is freed relative to the execution of its worker thread.

Scenario 1: Freed before the worker is scheduled

The brcmf_btcoex_info is deallocated before the worker is scheduled.
A race condition can occur when schedule_work(&bt_local->work) is called after the target memory has been freed. The sequence of events is detailed below:

CPU0 | CPU1 brcmf_btcoex_detach | brcmf_btcoex_timerfunc | bt_local->timer_on = false;
if (cfg->btcoex->timer_on) | ... | cancel_work_sync(); | ... | kfree(cfg->btcoex); // FREE | | schedule_work(&bt_local->work); // USE

Scenario 2: Freed after the worker is scheduled

The brcmf_btcoex_info is freed after the worker has been scheduled but before or during its execution. In this case, statements within the brcmf_btcoex_handler() — such as the container_of macro and subsequent dereferences of the brcmf_btcoex_info object will cause a use-after-free access. The following timeline illustrates this scenario:

CPU0 | CPU1 brcmf_btcoex_detach | brcmf_btcoex_timerfunc | bt_local->timer_on = false;
if (cfg->btcoex->timer_on) | ... | cancel_work_sync(); | ... | schedule_work(); // Reschedule | kfree(cfg->btcoex); // FREE | brcmf_btcoex_handler() // Worker /* | btci = container_of(....); // USE The kfree() above could | ...
also occur at any point | btci-> // USE during the worker's execution|
*/ |

To resolve the race conditions, drop the conditional check and call timer_shutdown_sync() directly. It can deactivate the timer reliably, regardless of its current state. Once stopped, the timer_on state is then set to false.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506412

File Name: tenable_ot_siemens_CVE-2025-39863.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.9

Percentile: 57.39

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2025-39863

CWE: 416