Siemens SIMATIC S7-1500 TM MFP Out-of-bounds Read (CVE-2026-43112)

high Tenable OT Security Plugin ID 506362

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

fs/smb/client: fix out-of-bounds read in cifs_sanitize_prepath

When cifs_sanitize_prepath is called with an empty string or a string containing only delimiters (e.g., '/'), the current logic attempts to check *(cursor2 - 1) before cursor2 has advanced. This results in an out-of-bounds read.

This patch adds an early exit check after stripping prepended delimiters. If no path content remains, the function returns NULL.

The bug was identified via manual audit and verified using a standalone test case compiled with AddressSanitizer, which triggered a SEGV on affected inputs.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506362

File Name: tenable_ot_siemens_CVE-2026-43112.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.3

Percentile: 53.65

CVSS v3

Risk Factor: High

Base Score: 8.8

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-43112

CWE: 125