Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-46056)

high Tenable OT Security Plugin ID 506274

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

Bluetooth: hci_event: fix potential UAF in SSP passkey handlers

hci_conn lookup and field access must be covered by hdev lock in hci_user_passkey_notify_evt() and hci_keypress_notify_evt(), otherwise the connection can be freed concurrently.

Extend the hci_dev_lock critical section to cover all conn usage in both handlers.

Keep the existing keypress notification behavior unchanged by routing the early exits through a common unlock path.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506274

File Name: tenable_ot_siemens_CVE-2026-46056.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.9

Percentile: 58.14

CVSS v3

Risk Factor: High

Base Score: 8.8

Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-46056

CWE: 20