Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-31500)

high Tenable OT Security Plugin ID 506249

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

Bluetooth: btintel: serialize btintel_hw_error() with hci_req_sync_lock

btintel_hw_error() issues two __hci_cmd_sync() calls (HCI_OP_RESET and Intel exception-info retrieval) without holding hci_req_sync_lock(). This lets it race against hci_dev_do_close() -> btintel_shutdown_combined(), which also runs
__hci_cmd_sync() under the same lock. When both paths manipulate hdev->req_status/req_rsp concurrently, the close path may free the response skb first, and the still-running hw_error path hits a slab-use-after-free in kfree_skb().

Wrap the whole recovery sequence in hci_req_sync_lock/unlock so it is serialized with every other synchronous HCI command issuer.

Below is the data race report and the kasan report:

BUG: data-race in __hci_cmd_sync_sk / btintel_shutdown_combined

read of hdev->req_rsp at net/bluetooth/hci_sync.c:199 by task kworker/u17:1/83:
__hci_cmd_sync_sk+0x12f2/0x1c30 net/bluetooth/hci_sync.c:200
__hci_cmd_sync+0x55/0x80 net/bluetooth/hci_sync.c:223 btintel_hw_error+0x114/0x670 drivers/bluetooth/btintel.c:254 hci_error_reset+0x348/0xa30 net/bluetooth/hci_core.c:1030

write/free by task ioctl/22580:
btintel_shutdown_combined+0xd0/0x360 drivers/bluetooth/btintel.c:3648 hci_dev_close_sync+0x9ae/0x2c10 net/bluetooth/hci_sync.c:5246 hci_dev_do_close+0x232/0x460 net/bluetooth/hci_core.c:526

BUG: KASAN: slab-use-after-free in sk_skb_reason_drop+0x43/0x380 net/core/skbuff.c:1202 Read of size 4 at addr ffff888144a738dc by task kworker/u17:1/83:
__hci_cmd_sync_sk+0x12f2/0x1c30 net/bluetooth/hci_sync.c:200
__hci_cmd_sync+0x55/0x80 net/bluetooth/hci_sync.c:223 btintel_hw_error+0x186/0x670 drivers/bluetooth/btintel.c:260

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506249

File Name: tenable_ot_siemens_CVE-2026-31500.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.9

Percentile: 57.96

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-31500

CWE: 20