Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2026-23230)

high Tenable OT Security Plugin ID 505404

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
smb: client: split cached_fid bitfields to avoid shared-byte RMW races is_open, has_lease and on_list are stored in the same bitfield byte in struct cached_fid but are updated in different code paths that may run concurrently. Bitfield assignments generate byte readmodifywrite operations (e.g. `orb $mask, addr` on x86_64), so updating one flag can restore stale values of the others. A possible interleaving is:
CPU1: load old byte (has_lease=1, on_list=1) CPU2: clear both flags (store 0) CPU1: RMW store (old | IS_OPEN) -> reintroduces cleared bits To avoid this class of races, convert these flags to separate bool fields.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-253495.html

https://support.industry.siemens.com/cs/ww/en/view/110002573/

Plugin Details

Severity: High

ID: 505404

File Name: tenable_ot_siemens_CVE-2026-23230.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 6/18/2026

Updated: 6/18/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: High

Base Score: 8.8

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:ruggedcom_rst2428p_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/2/2026

Vulnerability Publication Date: 2/18/2026

Reference Information

CVE: CVE-2026-23230