Siemens SIMATIC S7-1500 Improper Locking (CVE-2025-39773)

medium Tenable OT Security Plugin ID 505167

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
net: bridge: fix soft lockup in br_multicast_query_expired() When set multicast_query_interval to a large value, the local variable 'time' in br_multicast_send_query() may overflow. If the time is smaller than jiffies, the timer will expire immediately, and then call mod_timer() again, which creates a loop and may trigger the following soft lockup issue. watchdog: BUG: soft lockup - CPU#1 stuck for 221s! [rb_consumer:66] CPU: 1 UID: 0 PID: 66 Comm:
rb_consumer Not tainted 6.16.0+ #259 PREEMPT(none) Call Trace:
<IRQ> __netdev_alloc_skb+0x2e/0x3a0 br_ip6_multicast_alloc_query+0x212/0x1b70
__br_multicast_send_query+0x376/0xac0 br_multicast_send_query+0x299/0x510 br_multicast_query_expired.constprop.0+0x16d/0x1b0 call_timer_fn+0x3b/0x2a0 __run_timers+0x619/0x950 run_timer_softirq+0x11c/0x220 handle_softirqs+0x18e/0x560
__irq_exit_rcu+0x158/0x1a0 sysvec_apic_timer_interrupt+0x76/0x90 </IRQ> This issue can be reproduced with: ip link add br0 type bridge echo 1 > /sys/class/net/br0/bridge/multicast_querier echo 0xffffffffffffffff > /sys/class/net/br0/bridge/multicast_query_interval ip link set dev br0 up The multicast_startup_query_interval can also cause this issue. Similar to the commit 99b40610956a (net: bridge: mcast: add and enforce query interval minimum), add check for the query interval maximum to fix this issue.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-082556.html

Plugin Details

Severity: Medium

ID: 505167

File Name: tenable_ot_siemens_CVE-2025-39773.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 2/16/2026

Updated: 2/17/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v2

Risk Factor: Medium

Base Score: 4.6

Temporal Score: 3.4

Vector: CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C

CVSS Score Source: CVE-2025-39773

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Temporal Score: 4.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/10/2025

Vulnerability Publication Date: 6/10/2025

Reference Information

CVE: CVE-2025-39773

CWE: 667