Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2025-39683)

high Tenable OT Security Plugin ID 505154

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
tracing: Limit access to parser->buffer when trace_get_user failed When the length of the string written to set_ftrace_filter exceeds FTRACE_BUFF_MAX, the following KASAN alarm will be triggered: BUG:
KASAN: slab-out-of-bounds in strsep+0x18c/0x1b0 Read of size 1 at addr ffff0000d00bd5ba by task ash/165 CPU: 1 UID: 0 PID: 165 Comm:
ash Not tainted 6.16.0-g6bcdbd62bd56-dirty Hardware name:
linux,dummy-virt (DT) Call trace: show_stack+0x34/0x50 (C) dump_stack_lvl+0xa0/0x158 print_address_description.constprop.0+0x88/0x398 print_report+0xb0/0x280 kasan_report+0xa4/0xf0
__asan_report_load1_noabort+0x20/0x30 strsep+0x18c/0x1b0 ftrace_process_regex.isra.0+0x100/0x2d8 ftrace_regex_release+0x484/0x618 __fput+0x364/0xa58
____fput+0x28/0x40 task_work_run+0x154/0x278 do_notify_resume+0x1f0/0x220 el0_svc+0xec/0xf0 el0t_64_sync_handler+0xa0/0xe8 el0t_64_sync+0x1ac/0x1b0 The reason is that trace_get_user will fail when processing a string longer than FTRACE_BUFF_MAX, but not set the end of parser->buffer to 0. Then an OOB access will be triggered in ftrace_regex_release-> ftrace_process_regex->strsep->strpbrk. We can solve this problem by limiting access to parser->buffer when trace_get_user failed.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-082556.html

Plugin Details

Severity: High

ID: 505154

File Name: tenable_ot_siemens_CVE-2025-39683.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 2/16/2026

Updated: 2/17/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.0

CVSS v2

Risk Factor: Medium

Base Score: 6.2

Temporal Score: 4.6

Vector: CVSS2#AV:L/AC:L/Au:S/C:C/I:N/A:C

CVSS Score Source: CVE-2025-39683

CVSS v3

Risk Factor: High

Base Score: 7.1

Temporal Score: 6.2

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/10/2025

Vulnerability Publication Date: 6/10/2025

Reference Information

CVE: CVE-2025-39683

CWE: 125