Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49924)

medium Tenable OT Security Plugin ID 504761

Synopsis

The remote OT asset is affected by a vulnerability.

Description

fbdev: pxafb:use after free in pxafb_task(). In the pxafb_probe function, it calls the pxafb_init_fbinfo function, after which &fbi->task is associated with pxafb_task. Moreover, within this pxafb_init_fbinfo function, the pxafb_blank function within the &pxafb_ops struct is capable of scheduling work. If we remove the module which will call pxafb_remove to make cleanup, it will call unregister_framebuffer function which can call do_unregister_framebuffer to free fbi->fb through put_fb_info(fb_info), while the work mentioned above will be used.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 504761

File Name: tenable_ot_siemens_CVE-2024-49924.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 11/18/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Temporal Score: 4.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 8/12/2025

Vulnerability Publication Date: 8/12/2025

Reference Information

CVE: CVE-2024-49924

CWE: 20

ICSA: 25-226-07