Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46719)

medium Tenable OT Security Plugin ID 504659

Synopsis

The remote OT asset is affected by a vulnerability.

Description

usb: typec: ucsi: Fix null pointer dereference in trace ucsi_register_altmode checks IS_ERR for the alt pointer and treats NULL as valid. When CONFIG_TYPEC_DP_ALTMODE is not enabled, ucsi_register_displayport returns NULL which causes a NULL pointer dereference in trace. Rather than return NULL, call typec_port_register_altmode to register DisplayPort alternate mode as a non-controllable mode when CONFIG_TYPEC_DP_ALTMODE is not enabled.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 504659

File Name: tenable_ot_siemens_CVE-2024-46719.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 11/18/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Temporal Score: 4.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 8/12/2025

Vulnerability Publication Date: 8/12/2025

Reference Information

CVE: CVE-2024-46719

CWE: 20

ICSA: 25-226-07