Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50268)

medium Tenable OT Security Plugin ID 504622

Synopsis

The remote OT asset is affected by a vulnerability.

Description

usb: typec: fix potential out of bounds in ucsi_ccg_update_set_new_cam_cmd(). The *cmd variable can be controlled by the user via debugfs. That means new_cam can be as high as 255 while the size of the uc->updated[] array is UCSI_MAX_ALTMODES (30). The call tree is: ucsi_cmd() // val comes from simple_attr_write_xsigned() -> ucsi_send_command() -> ucsi_send_command_common() -> ucsi_run_command() // calls ucsi->ops->sync_control() -> ucsi_ccg_sync_control().

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 504622

File Name: tenable_ot_siemens_CVE-2024-50268.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 11/18/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.0

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Temporal Score: 4.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 8/12/2025

Vulnerability Publication Date: 8/12/2025

Reference Information

CVE: CVE-2024-50268

CWE: 20

ICSA: 25-226-07