Siemens SIMATIC S7-1500 Improper Handling of Values (CVE-2024-44965)

medium Tenable OT Security Plugin ID 504059

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
x86/mm: Fix pti_clone_pgtable() alignment assumption Guenter reported dodgy crashes on an i386-nosmp build using GCC-11 that had the form of endless traps until entry stack exhaust and then #DF from the stack guard. It turned out that pti_clone_pgtable() had alignment assumptions on the start address, notably it hard assumes start is PMD aligned. This is true on x86_64, but very much not true on i386. These assumptions can cause the end condition to malfunction, leading to a 'short' clone. Guess what happens when the user mapping has a short copy of the entry text? Use the correct increment form for addr to avoid alignment assumptions.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-398330.html

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://support.industry.siemens.com/cs/ww/en/view/109478459/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 504059

File Name: tenable_ot_siemens_CVE-2024-44965.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 11/13/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/12/2023

Vulnerability Publication Date: 12/12/2023

Reference Information

CVE: CVE-2024-44965

CWE: 229

ICSA: 25-226-07