Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2025-29087)

medium Tenable OT Security Plugin ID 503988

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In SQLite, the concat_ws() SQL function can cause memory to be written beyond the end of a malloc-allocated buffer. If the separator argument is attacker-controlled and has a large string (e.g., 2MB or more), an integer overflow occurs in calculating the size of the result buffer, and thus malloc may not allocate enough memory.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-398330.html

https://cert-portal.siemens.com/productcert/html/ssa-994087.html

https://support.industry.siemens.com/cs/ww/en/view/109989951/

https://support.industry.siemens.com/cs/ww/en/view/109478459/

Plugin Details

Severity: Medium

ID: 503988

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 11/13/2025

Updated: 11/13/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Temporal Score: 4.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/12/2023

Vulnerability Publication Date: 12/12/2023

Reference Information

CVE: CVE-2025-29087

CWE: 190