Siemens SIMATIC S7-1500 Double Free (CVE-2025-32988)

medium Tenable OT Security Plugin ID 503937

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A flaw was found in GnuTLS. A double-free vulnerability exists in GnuTLS due to incorrect ownership handling in the export logic of Subject Alternative Name (SAN) entries containing an otherName. If the type-id OID is invalid or malformed, GnuTLS will call asn1_delete_structure() on an ASN.1 node it does not own, leading to a double-free condition when the parent function or caller later attempts to free the same structure. This vulnerability can be triggered using only public GnuTLS APIs and may result in denial of service or memory corruption, depending on allocator behavior.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-082556.html

https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-10

Plugin Details

Severity: Medium

ID: 503937

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 11/13/2025

Updated: 11/13/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 5.0

CVSS v3

Risk Factor: Medium

Base Score: 6.5

Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/10/2025

Vulnerability Publication Date: 6/10/2025

Reference Information

CVE: CVE-2025-32988

CWE: 415

ICSA: 23-348-10