Siemens SIMATIC Devices Improper Input Validation (CVE-2024-27437)

medium Tenable OT Security Plugin ID 503698

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
vfio/pci: Disable auto-enable of exclusive INTx IRQ Currently for devices requiring masking at the irqchip for INTx, ie. devices without DisINTx support, the IRQ is enabled in request_irq() and subsequently disabled as necessary to align with the masked status flag. This presents a window where the interrupt could fire between these events, resulting in the IRQ incrementing the disable depth twice. This would be unrecoverable for a user since the masked flag prevents nested enables through vfio. Instead, invert the logic using IRQF_NO_AUTOEN such that exclusive INTx is never auto-enabled, then unmask as required.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503698

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/5/2024

Reference Information

CVE: CVE-2024-27437

CWE: 20