Siemens SIMATIC Devices Operation on a Resource after Expiration or Release (CVE-2024-57929)

medium Tenable OT Security Plugin ID 503631

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
dm array: fix releasing a faulty array block twice in dm_array_cursor_end When dm_bm_read_lock() fails due to locking or checksum errors, it releases the faulty block implicitly while leaving an invalid output pointer behind. The caller of dm_bm_read_lock() should not operate on this invalid dm_block pointer, or it will lead to undefined result. For example, the dm_array_cursor incorrectly caches the invalid pointer on reading a faulty array block, causing a double release in dm_array_cursor_end(), then hitting the BUG_ON in dm-bufio cache_put().

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503631

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.0

CVSS v3

Risk Factor: Medium

Base Score: 6.7

Vector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-57929

CWE: 672