Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-47699)

medium Tenable OT Security Plugin ID 503629

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
nilfs2: fix potential null-ptr-deref in nilfs_btree_insert() Patch series nilfs2: fix potential issues with empty b-tree nodes. This series addresses three potential issues with empty b-tree nodes that can occur with corrupted filesystem images, including one recently discovered by syzbot. This patch (of 3): If a b-tree is broken on the device, and the b-tree height is greater than 2 (the level of the root node is greater than 1) even if the number of child nodes of the b-tree root is 0, a NULL pointer dereference occurs in nilfs_btree_prepare_insert(), which is called from nilfs_btree_insert(). This is because, when the number of child nodes of the b-tree root is 0, nilfs_btree_do_lookup() does not set the block buffer head in any of path[x].bp_bh, leaving it as the initial value of NULL, but if the level of the b-tree root node is greater than 1, nilfs_btree_get_nonroot_node(), which accesses the buffer memory of path[x].bp_bh, is called. Fix this issue by adding a check to nilfs_btree_root_broken(), which performs sanity checks when reading the root node from the device, to detect this inconsistency. Thanks to Lizhi Xu for trying to solve the bug and clarifying the cause early on.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 503629

File Name: tenable_ot_siemens_CVE-2024-47699.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:simatic_s7-1500_tm_mfp, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-47699

CWE: 476

ICSA: 25-226-07