Siemens SIMATIC Devices Improper Validation of Specified Type of Input (CVE-2024-35897)

medium Tenable OT Security Plugin ID 503624

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
netfilter: nf_tables: discard table flag update with pending basechain deletion Hook unregistration is deferred to the commit phase, same occurs with hook updates triggered by the table dormant flag. When both commands are combined, this results in deleting a basechain while leaving its hook still registered in the core.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503624

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-35897

CWE: 1287