Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Handling of Exceptional Conditions (CVE-2024-50001)

medium Tenable OT Security Plugin ID 503555

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
net/mlx5: Fix error path in multi-packet WQE transmit Remove the erroneous unmap in case no DMA mapping was established The multi- packet WQE transmit code attempts to obtain a DMA mapping for the skb.
This could fail, e.g. under memory pressure, when the IOMMU driver just can't allocate more memory for page tables. While the code tries to handle this in the path below the err_unmap label it erroneously unmaps one entry from the sq's FIFO list of active mappings. Since the current map attempt failed this unmap is removing some random DMA mapping that might still be required. If the PCI function now presents that IOVA, the IOMMU may assumes a rogue DMA access and e.g. on s390 puts the PCI function in error state. The erroneous behavior was seen in a stress-test environment that created memory pressure.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 503555

File Name: tenable_ot_siemens_CVE-2024-50001.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:simatic_s7-1500_tm_mfp, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-50001

CWE: 755

ICSA: 25-226-07