Siemens SIMATIC Devices Improper Locking (CVE-2024-50210)

medium Tenable OT Security Plugin ID 503478

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
posix-clock: posix-clock: Fix unbalanced locking in pc_clock_settime() If get_clock_desc() succeeds, it calls fget() for the clockid's fd, and get the clk->rwsem read lock, so the error path should release the lock to make the lock balance and fput the clockid's fd to make the refcount balance and release the fd related resource. However the below commit left the error path locked behind resulting in unbalanced locking. Check timespec64_valid_strict() before get_clock_desc() to fix it, because the ts is not changed after that. [[email protected]: fixed commit message typo]

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503478

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-50210

CWE: 667