Siemens SIMATIC Devices Improper Input Validation (CVE-2024-38560)

medium Tenable OT Security Plugin ID 503439

Synopsis

The remote OT asset is affected by a vulnerability.

Description

scsi: bfa: Ensure the copied buf is NUL terminated Currently, we allocate a nbytes-sized kernel buffer and copy nbytes from userspace to that buffer. Later, we use sscanf on this buffer but we don't ensure that the string is terminated inside the buffer, this can lead to OOB read when using sscanf.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503439

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.0

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-38560

CWE: 20