Siemens SCALANCE W1750D Command Injection (CVE-2018-7084)

critical Tenable OT Security Plugin ID 500886

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A command injection vulnerability is present that permits an unauthenticated user with access to the Aruba Instant web interface to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete files, or reboot the device. Workaround: Block access to the Aruba Instant web interface from all untrusted users. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.1

- A command injection vulnerability is present that permits an unauthenticated user with access to the Aruba Instant web interface to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete files, or reboot the device. Workaround: Block access to the Aruba Instant web interface from all untrusted users.
Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.1 (CVE-2018-7084)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens recommends users upgrade to Version 8.4.0.1 or later, which can be downloaded from the following link:

https://support.industry.siemens.com/cs/us/en/view/109766816/

Siemens has identified the following specific workarounds and mitigations that users can apply to reduce the risk:

- Restrict access to the web-based management interface to the internal or VPN network.
- Do not browse other websites and do not click on external links while being authenticated to the administrative web interface.
- Apply appropriate strategies for mitigation.

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security, and following the recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at:

https://www.siemens.com/industrialsecurity

For more information on these vulnerabilities and associated software updates, please see Siemens security advisory SSA-549547 on their website:

https://www.siemens.com/cert/advisories

See Also

https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt

https://www.cisa.gov/news-events/ics-advisories/icsa-19-134-07

https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf

http://www.securityfocus.com/bid/108374

Plugin Details

Severity: Critical

ID: 500886

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 3/20/2023

Updated: 7/24/2023

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v2

Risk Factor: Critical

Base Score: 10

Temporal Score: 7.4

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2018-7084

CVSS v3

Risk Factor: Critical

Base Score: 9.8

Temporal Score: 8.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_w1750d_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 5/10/2019

Vulnerability Publication Date: 5/10/2019

Reference Information

CVE: CVE-2018-7084

CWE: 78