Updated CVEs

IDDescriptionSeverity
CVE-2019-11687An issue was discovered in the DICOM Part 10 File Format in the NEMA DICOM Standard 1995 through 2019b and continuing in current implementations. The 128-byte preamble of a DICOM file that complies with this specification can contain arbitrary executable headers for multiple operating systems, including Portable Executable (PE) files for Windows and Executable and Linkable Format (ELF) files for Linux-based systems. This space is left unspecified so that dual-purpose files can be created. For example, dual-purpose TIFF/DICOM files are used in digital whole slide imaging applications in medicine. This design flaw enables system-wide compromise as malicious DICOM files are routinely shared between medical devices and hospital systems and transported via removable media for patient care coordination. To exploit this vulnerability, someone must execute the maliciously crafted file. These files can be executable even with the .dcm file extension. Anti-malware configurations at healthcare facilities often ignore medical imagery. DICOM files exist on systems that process protected health information, and successful exploitation could result in violations of regulatory compliance requirements such as HIPAA and FDA postmarket obligations.
high
CVE-2014-9190Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
critical
CVE-2014-9188Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
critical
CVE-2010-0425modules/arch/win32/mod_isapi.c in mod_isapi in the Apache HTTP Server 2.0.37 through 2.0.63, 2.2.0 through 2.2.14, and 2.3.x before 2.3.7, when running on Windows, does not ensure that request processing is complete before calling isapi_unload for an ISAPI .dll module, which allows remote attackers to execute arbitrary code via unspecified vectors related to a crafted request, a reset packet, and "orphaned callback pointers."
critical
CVE-2025-7952A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
low
CVE-2025-7933A vulnerability classified as critical was found in Campcodes Sales and Inventory System 1.0. This vulnerability affects unknown code of the file /pages/settings_update.php of the component Setting Handler. The manipulation of the argument ID leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
medium
CVE-2025-7914A vulnerability has been found in Tenda AC6 15.03.06.50 and classified as critical. Affected by this vulnerability is the function setparentcontrolinfo of the component httpd. The manipulation leads to buffer overflow. The attack can be launched remotely.
high
CVE-2025-7913A vulnerability, which was classified as critical, was found in TOTOLINK T6 4.1.5cu.748_B20211015. Affected is the function updateWifiInfo of the component MQTT Service. The manipulation of the argument serverIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7912A vulnerability, which was classified as critical, has been found in TOTOLINK T6 4.1.5cu.748_B20211015. This issue affects the function recvSlaveUpgstatus of the component MQTT Service. The manipulation of the argument s leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7905A vulnerability has been found in itsourcecode Insurance Management System 1.0 and classified as critical. This vulnerability affects unknown code of the file /insertPayment.php. The manipulation of the argument recipt_no leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
low
CVE-2025-7904A vulnerability, which was classified as critical, was found in itsourcecode Insurance Management System 1.0. This affects an unknown part of the file /insertNominee.php. The manipulation of the argument nominee_id leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
low
CVE-2025-7862A vulnerability has been found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this vulnerability is the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument telnet_enabled with the input 1 leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
medium
CVE-2025-7855A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely.
high
CVE-2025-7854A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7853A vulnerability was found in Tenda FH451 1.0.0.9. It has been rated as critical. This issue affects the function fromSetIpBind of the file /goform/SetIpBind. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7840A vulnerability was found in Campcodes Online Movie Theater Seat Reservation System 1.0. It has been classified as problematic. This affects an unknown part of the file /index.php?page=reserve of the component Reserve Your Seat Page. The manipulation of the argument Firstname/Lastname leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
low
CVE-2025-7838A vulnerability has been found in Campcodes Online Movie Theater Seat Reservation System 1.0 and classified as critical. This vulnerability affects unknown code of the file /admin/manage_seat.php. The manipulation of the argument ID leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
medium
CVE-2025-7837A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this issue is the function recvSlaveStaInfo of the component MQTT Service. The manipulation of the argument dest leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7807A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. This issue affects the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7806A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7805A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7796A vulnerability, which was classified as critical, was found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7795A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. Affected by this issue is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7794A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7793A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function formWebTypeLibrary of the file /goform/webtypelibrary. The manipulation of the argument webSiteId leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7792A vulnerability was found in Tenda FH451 1.0.0.9. It has been rated as critical. This issue affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7790A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been classified as critical. This affects an unknown part of the file /menu_nat.asp of the component HTTP Request Handler. The manipulation of the argument out_addr/in_addr/out_port/proto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7762A vulnerability, which was classified as critical, has been found in D-Link DI-8100 16.07.26A1. This issue affects some unknown processing of the file /menu_nat_more.asp of the component HTTP Request Handler. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7758A vulnerability, which was classified as critical, has been found in TOTOLINK T6 up to 4.1.5cu.748_B20211015. Affected by this issue is the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
high
CVE-2025-7427Uncontrolled Search Path Element in Arm Development Studio before 2025 may allow an attacker to perform a DLL hijacking attack. Successful exploitation could lead to local arbitrary code execution in the context of the user running Arm Development Studio.
medium
CVE-2025-7035The Media Library Assistant plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the plugin's mla_tag_cloud and mla_term_list shortcodes in all versions up to, and including, 3.26 due to insufficient input sanitization and output escaping on user supplied attributes. This makes it possible for authenticated attackers, with contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
medium
CVE-2025-6558Insufficient validation of untrusted input in ANGLE and GPU in Google Chrome prior to 138.0.7204.157 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High)
high
CVE-2025-54371Rejected reason: This CVE is a duplicate of another CVE.
No Score
CVE-2025-54313eslint-config-prettier 8.10.1, 9.1.1, 10.1.6, and 10.1.7 has embedded malicious code for a supply chain compromise. Installing an affected package executes an install.js file that launches the node-gyp.dll malware on Windows.
high
CVE-2025-54309CrushFTP 10 before 10.8.5 and 11 before 11.3.4_23, when the DMZ proxy feature is not used, mishandles AS2 validation and consequently allows remote attackers to obtain admin access via HTTPS, as exploited in the wild in July 2025.
critical
CVE-2025-53528Cadwyn creates production-ready community-driven modern Stripe-like API versioning in FastAPI. In versions before 5.4.3, the version parameter of the "/docs" endpoint is vulnerable to a Reflected XSS (Cross-Site Scripting) attack. This XSS would notably allow an attacker to execute JavaScript code on a user's session for any application based on Cadwyn via a one-click attack. The vulnerability has been fixed in version 5.4.3.
high
CVE-2025-53519A vulnerability exists in Advantech iView versions prior to 5.7.05 build 7057, which could allow a reflected cross-site scripting (XSS) attack. By manipulating specific parameters, an attacker could execute unauthorized scripts in the user's browser, potentially leading to information disclosure or other malicious activities.
medium
CVE-2025-53475A vulnerability exists in Advantech iView that could allow for SQL injection and remote code execution through NetworkServlet.getNextTrapPage(). This issue requires an authenticated attacker with at least user-level privileges. Certain parameters in this function are not properly sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.
high
CVE-2025-52924In One Identity OneLogin before 2025.2.0, the SQL connection "application name" is set based on the value of an untrusted X-RequestId HTTP request header.
medium
CVE-2025-52577A vulnerability exists in Advantech iView that could allow SQL injection and remote code execution through NetworkServlet.archiveTrapRange(). This issue requires an authenticated attacker with at least user-level privileges. Certain input parameters are not properly sanitized, allowing an attacker to perform SQL injection and potentially execute code in the context of the 'nt authority\local service' account.
high
CVE-2025-49738Improper link resolution before file access ('link following') in Microsoft PC Manager allows an authorized attacker to elevate privileges locally.
high
CVE-2025-48891A vulnerability exists in Advantech iView that could allow for SQL injection through the CUtils.checkSQLInjection() function. This vulnerability can be exploited by an authenticated attacker with at least user-level privileges, potentially leading to information disclosure or a denial-of-service condition.
high
CVE-2025-47988Improper control of generation of code ('code injection') in Azure Monitor Agent allows an unauthorized attacker to execute code over an adjacent network.
high
CVE-2025-47268ping in iputils before 20250602 allows a denial of service (application error or incorrect data collection) via a crafted ICMP Echo Reply packet, because of a signed 64-bit integer overflow in timestamp multiplication.
medium
CVE-2025-47178Improper neutralization of special elements used in an sql command ('sql injection') in Microsoft Configuration Manager allows an authorized attacker to execute code over an adjacent network.
high
CVE-2025-46704A vulnerability exists in Advantech iView in NetworkServlet.processImportRequest() that could allow for a directory traversal attack. This issue requires an authenticated attacker with at least user-level privileges. A specific parameter is not properly sanitized or normalized, potentially allowing an attacker to determine the existence of arbitrary files on the server.
medium
CVE-2025-46001An arbitrary file upload vulnerability in the is_allowed_file_type() function of Filemanager v2.3.0 allows attackers to execute arbitrary code via uploading a crafted PHP file.
critical
CVE-2025-45986Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 werediscovered to contain a command injection vulnerability via the mac parameter in the bs_SetMacBlack function.
critical
CVE-2025-41663For u-link Management API an unauthenticated remote attacker in a man-in-the-middle position can inject arbitrary commands in responses returned by WWH servers, which are then executed with elevated privileges. To get into such a position, clients would need to use insecure proxy configurations.
critical
CVE-2025-41662Rejected reason: CVE-2025-41662 is considered redundant or unnecessary and thus should be withdrawn. Instead, a new CVE CVE-2025-41687 has been reserved to better reflect the updated analysis.
No Score