CVE-2026-85068

low

Description

Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.8.5, ippon_command in drivers/blazer_usb.c partially initializes char tmp[64] with a short Megatec status query and then passes a fixed eight-byte chunk to usb_control_msg. A malicious firmware-controlled USB device presenting the Mustek Powermust VID 0x06da and Mustek Powermust PID 0x0003 matches blazer_usb_id, selects ippon_subdriver, and can receive the uninitialized trailing stack bytes during normal polling. The disclosure is bounded and read-only, requires physical or supply-chain access to the USB bus, and has no established integrity or availability impact. This issue is scheduled to be fixed in version 2.8.6.

References

https://github.com/networkupstools/nut/security/advisories/GHSA-fjxc-2vpv-mqc8

https://github.com/networkupstools/nut/pull/3529

https://github.com/networkupstools/nut/commit/30d56d4282f823949b40763d5c76461c7dd107b3

https://euvd.enisa.europa.eu/vulnerability/EUVD-2026-117878

Details

Source: Mitre, NVD

Published: 2026-11-05

Updated: 2026-11-05

Risk Information

CVSS v2

Base Score: 2.1

Vector: CVSS2#AV:L/AC:L/Au:N/C:P/I:N/A:N

Severity: Low

CVSS v3

Base Score: 2.4

Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Severity: Low

EPSS

EPSS: 0.00151