Description

Accesses to the CMOS memory contents are done using an indirect IO port pair. Therefore Xen needs to cache the guest chosen index, and one of the usages of the index didn't take the necessary locking to avoid concurrent changes. As a result, a guest could change the index after it being checked, causing a subsequent out-of-bound read access to the contents of an array.

References

https://xenbits.xenproject.org/xsa/advisory-503.html

http://xenbits.xen.org/xsa/advisory-503.html

http://www.openwall.com/lists/oss-security/2026/07/28/19

Details

Source: Mitre, NVD

Published: 2026-07-28

Updated: 2026-07-28

Risk Information

CVSS v2

Base Score: 7.8

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:N/A:N

Severity: High

CVSS v3

Base Score: 7.5

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N