CVE-2026-54429

medium

Description

A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.

References

https://cert-portal.siemens.com/productcert/html/ssa-828211.html

Details

Source: Mitre, NVD

Published: 2026-07-14

Updated: 2026-07-14

Risk Information

CVSS v2

Base Score: 6.1

Vector: CVSS2#AV:A/AC:L/Au:N/C:N/I:N/A:C

Severity: Medium

CVSS v3

Base Score: 7.4

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Severity: High

CVSS v4

Base Score: 6

Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L

Severity: Medium

EPSS

EPSS: 0.00215