CVE-2026-4638

high

Description

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

References

https://www.paessler.com/prtg/prtg-network-monitor

https://www.paessler.com/de/download/

https://r.sec-consult.com/paessler

https://paessler.freshdesk.com/en/support/solutions/articles/76000088640

https://euvd.enisa.europa.eu/vulnerability/EUVD-2026-85847

Details

Source: Mitre, NVD

Published: 2026-09-24

Updated: 2026-09-24

Risk Information

CVSS v2

Base Score: 5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N

Severity: Medium

CVSS v3

Base Score: 6.5

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Severity: Medium

CVSS v4

Base Score: 7.1

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Severity: High

EPSS

EPSS: 0.00268