CVE-2026-34021

high

Description

The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.

References

https://wertheim-safes.com/safe-deposit-boxes/

https://sec-consult.com/vulnerability-lab/advisory/multiple-vulnerabilities-in-wertheim-safecontroller-hardware-for-vault-rooms-safe-deposit-locker-system-microcontroller/

https://r.sec-consult.com/wertdev

Details

Source: Mitre, NVD

Published: 2026-06-15

Updated: 2026-06-15

Risk Information

CVSS v2

Base Score: 7.5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P

Severity: High

CVSS v3

Base Score: 9.8

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Severity: Critical

CVSS v4

Base Score: 8.6

Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N

Severity: High

EPSS

EPSS: 0.00196