CVE-2026-133001

medium

Description

FlowIntel contains an authorization flaw in its duplicate alert ingestion logic. When a duplicate alert is received and its content is updated, the ownership and visibility scope fields (owner user and owner organization) were not refreshed to reflect the connector's current scope. As a result, an alert that was originally created under a broader visibility scope retained that broader scope even after the connector's scope was narrowed or changed. This means that users or organizations that should no longer have visibility into a given alert could continue to access it, because the stale ownership fields were never updated during the duplicate-update path. The issue affected all duplicate updates, including those involving alerts in terminal review states and those recovered from uniqueness conflicts. Security impact: - Unauthorized disclosure of security alert content to users or organizations outside the intended visibility scope. - Stale access persists indefinitely until the alert is independently re-scoped or deleted. Affected version: <4.1.0.

References

https://github.com/flowintel/flowintel/commit/c158e1bdcebda70dd4a1395f7ac1a0c14ac5d362

https://euvd.enisa.europa.eu/vulnerability/EUVD-2026-129551

Details

Source: Mitre, NVD

Published: 2026-11-19

Updated: 2026-11-24

Risk Information

CVSS v2

Base Score: 5.5

Vector: CVSS2#AV:N/AC:L/Au:S/C:P/I:P/A:N

Severity: Medium

CVSS v3

Base Score: 7.2

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N

Severity: High

CVSS v4

Base Score: 5.3

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

Severity: Medium

EPSS

EPSS: 0.00312