CVE-2026-124759

high

Description

P-Net before 1.0.4 routes a received RTA alarm frame to an Application Relationship using only the destination alarm reference in the frame, without checking the source of the frame. A host with ADJACENT network access can abort an established Application Relationship with a single alarm ERROR frame, or deliver forged alarm notifications with chosen type, slot, subslot, USI and payload to the application.

References

https://rt-labs.com/wp-content/uploads/2026/11/RRTL-261109-01.pdf

https://euvd.enisa.europa.eu/vulnerability/EUVD-2026-125296

Details

Source: Mitre, NVD

Published: 2026-11-13

Updated: 2026-11-17

Risk Information

CVSS v2

Base Score: 7.5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P

Severity: High

CVSS v3

Base Score: 9.1

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

Severity: Critical

CVSS v4

Base Score: 7.1

Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N

Severity: High

EPSS

EPSS: 0.00106