An improper authentication security issue exists within the 1794-AENTR adapter's embedded web server. The vulnerability allows an unauthenticated attacker to change the device's web interface password by sending a crafted HTTP GET request to a specific endpoint, without any prior authentication being required. If exploited, this could lead to unauthorized access, account takeover, and loss of the device’s embedded web server’s availability.
https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html
Published: 2026-06-16
Updated: 2026-06-16
Base Score: 7.5
Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P
Severity: High
Base Score: 9.8
Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Severity: Critical
Base Score: 8.8
Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N
Severity: High