CVE-2025-47421

high

Description

Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in CRESTRON TOUCHSCREENS x70 allows Argument Injection.This issue affects TOUCHSCREENS x70: from 3.001.0031.001 through 3.001.0034.001. A specially crafted SCP command sent via SSH login string can lead a valid administrator user to gain Privileged Operating System access on the device. Following Products Models are affected: TSW-x70 TSW-x60 TST-1080 AM-3000/3100/3200 Soundbar VB70 HD-PS622/621/402 HD-TXU-RXU-4kZ-211 HD-MDNXM-4KZ-E *Note: additional firmware updates will be published once made available

References

https://security.crestron.com

Details

Source: Mitre, NVD

Published: 2025-09-03

Updated: 2025-09-04

Risk Information

CVSS v2

Base Score: 7.5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P

Severity: High

CVSS v3

Base Score: 9.8

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Severity: Critical

CVSS v4

Base Score: 8.6

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Severity: High

EPSS

EPSS: 0.00037