CVE-2025-30046

critical

Description

In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.

References

https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html

https://euvd.enisa.europa.eu/vulnerability/EUVD-2025-211177

https://cert.pl/en/posts/2026/10/CVE-2025-30043/

Details

Source: Mitre, NVD

Published: 2026-10-23

Updated: 2026-10-23

Risk Information

CVSS v2

Base Score: 8.3

Vector: CVSS2#AV:A/AC:L/Au:N/C:C/I:C/A:C

Severity: High

CVSS v3

Base Score: 8.8

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Severity: High

CVSS v4

Base Score: 9

Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Severity: Critical

EPSS

EPSS: 0.00263