CVE-2024-2984

high

Description

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

References

https://vuldb.com/?submit.301275

https://vuldb.com/?id.258153

https://vuldb.com/?ctiid.258153

https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formSetCfm.md

Details

Source: Mitre, NVD

Published: 2024-03-27

Updated: 2024-04-11

Risk Information

CVSS v2

Base Score: 7.5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P

Severity: High

CVSS v3

Base Score: 8.8

Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Severity: High