CVE-2023-24512

medium

Description

On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision

References

https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086

Details

Source: Mitre, NVD

Published: 2023-04-25

Updated: 2026-06-17

Risk Information

CVSS v2

Base Score: 6.8

Vector: CVSS2#AV:N/AC:L/Au:S/C:N/I:C/A:N

Severity: Medium

CVSS v3

Base Score: 6.5

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N

Severity: Medium

EPSS

EPSS: 0.00191