CVE-2020-10276

critical

Description

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

References

https://github.com/aliasrobotics/RVD/issues/2558

Details

Source: Mitre, NVD

Published: 2020-06-24

Updated: 2026-06-17

Risk Information

CVSS v2

Base Score: 7.5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P

Severity: High

CVSS v3

Base Score: 9.8

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Severity: Critical

EPSS

EPSS: 0.00363