Description

On QFX and PTX Series, receipt of a malformed packet for J-Flow sampling might crash the FPC (Flexible PIC Concentrator) process which causes all interfaces to go down. By continuously sending the offending packet, an attacker can repeatedly crash the FPC process causing a sustained Denial of Service (DoS). This issue affects both IPv4 and IPv6 packet processing. Affected releases are Juniper Networks Junos OS on QFX and PTX Series: 17.4 versions prior to 17.4R2-S1, 17.4R3; 18.1 versions prior to 18.1R3-S1; 18.2 versions prior to 18.2R1-S3, 18.2R2; 17.2X75 versions prior to 17.2X75-D91, 17.2X75-D100.

References

http://www.securityfocus.com/bid/106556

https://kb.juniper.net/JSA10914

Details

Source: MITRE

Published: 2019-01-15

Updated: 2020-07-22

Type: CWE-19

Risk Information

CVSS v2

Base Score: 5

Vector: AV:N/AC:L/Au:N/C:N/I:N/A:P

Impact Score: 2.9

Exploitability Score: 10

Severity: MEDIUM

CVSS v3

Base Score: 7.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Impact Score: 3.6

Exploitability Score: 3.9

Severity: HIGH

Tenable Plugins

View all (1 total)

IDNameProductFamilySeverity
121126Junos OS: FPC process crashes after J-Flow processes a malformed packet (JSA10914)NessusJunos Local Security Checks
high