CVE-2018-0468

high
New! CVE Severity Now Using CVSS v3

The calculated severity for CVEs has been updated to use CVSS v3 by default. CVEs that do not have a CVSS v3 score will fall back CVSS v2 for calculating severity. Severity display preferences can be toggled in the settings dropdown.

Description

A vulnerability in the configuration of a local database installed as part of the Cisco Energy Management Suite (CEMS) could allow an authenticated, local attacker to access and alter confidential data. The vulnerability is due to the installation of the PostgreSQL database with unchanged default access credentials. An attacker could exploit this vulnerability by logging in to the machine where CEMS is installed and establishing a local connection to the database. The fix for this vulnerability randomizes the database access password in new installations; however, the fix will not change the password for existing installations. Users are required to manually change the password, as documented in the Workarounds section of this advisory. There are workarounds that address this vulnerability.

References

http://www.securityfocus.com/bid/106124

https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181204-ems-sql-passwrd

https://www.tenable.com/security/research/tra-2018-42

Details

Source: MITRE

Published: 2018-12-04

Updated: 2019-01-02

Type: CWE-798

Risk Information

CVSS v2

Base Score: 4.6

Vector: AV:L/AC:L/Au:N/C:P/I:P/A:P

Impact Score: 6.4

Exploitability Score: 3.9

Severity: MEDIUM

CVSS v3

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Impact Score: 5.9

Exploitability Score: 1.8

Severity: HIGH

Tenable Plugins

View all (1 total)

IDNameProductFamilySeverity
152699Cisco Energy Management Suite Default PostgreSQL Password VulnerabilityNessusCISCO
high