CVE-2017-20236

critical

Description

ProSoft Technology ICX35-HWC versions 1.3 and prior cellular gateways contain an input validation vulnerability in the web user interface that allows remote attackers to inject and execute system commands by submitting malicious input through unvalidated fields. Attackers can exploit this vulnerability to gain root privileges and execute arbitrary commands on the device through the accessible web interface.

References

https://www.vulncheck.com/advisories/prosoft-technology-icx35-hwc-command-injection-via-web-interface

https://assets.belden.com/m/1116a05ab702b2ba/original/Security-Bulletin-User-Interface-ProSoft-ICX35-BSECV-2017-10.pdf

Details

Source: Mitre, NVD

Published: 2026-04-03

Updated: 2026-04-22

Risk Information

CVSS v2

Base Score: 10

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

Severity: Critical

CVSS v3

Base Score: 9.8

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Severity: Critical

CVSS v4

Base Score: 9.3

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Severity: Critical

EPSS

EPSS: 0.00073