| 720074 | Honeywell Midas Gas Detectors Path Cleartext Transmission | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720078 | Rockwell Automation/Allen-Bradley CompactLogix 1769-Lx < 28.011 XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720081 | Schneider Electric PowerLogic PM8ECC < 2.651 XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720089 | Mitsubishi MELSEC-Q Ethernet Interface Modules Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720093 | Siemens Desigo PX Web Modules Insufficient Entropy | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720095 | Rockwell Automation/Allen-Bradley Multiple Devices Cleartext Transmission | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720097 | Emerson DeltaV Wireless I/O Cards (WIOC) 13.3 Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720101 | Rockwell Automation/Allen-Bradley MicroLogix 1400 Series B FRN < 21.2 Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720105 | Siemens SICAM RTUs SM-2556 COM Modules Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720106 | Siemens SICAM RTUs SM-2556 COM Modules XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720112 | Schneider Electric Modicon M340 Controllers Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720117 | Schneider Electric Modicon Modbus Protocol Violation of Secure Design Principles | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720119 | Schneider Electric Modicon Modbus Protocol Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720122 | Siemens OZW Devices Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720128 | Rockwell Automation/Allen-Bradley PanelView Plus 6 HMIs Missing Authorization | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720129 | ABB VSN300 WiFi Logger Card Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720135 | Yokogawa STARDOM Controllers < R4.02 Hardcoded Credentials | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720147 | Emerson ControlWave Micro <= 05.78.00 Buffer Overflow | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720153 | Schneider Electric Modicon M221 < 1.6.2.0 Password Overwrite | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720156 | Rockwell Automation 1756-EWEB <= 5.001 and 1768-EWEB <= 2.005 SNMP Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720160 | Schneider Electric OPC Factory Server (OFS) <= 3.5 Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720161 | Schneider Electric Modicon TM221CE16R 1.3.3.3 Information Disclosure | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720170 | Siemens SIMATIC S7-400 (all versions) and S7-410 < 8.2.1 Multiple Connections DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720171 | Siemens SIMATIC S7-400 (all versions) and S7-410 < 8.2.1 Multiple Packets DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720174 | Emerson Multiple RTUs Network Beacon Leak Metadata | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720177 | Omron NS HMIs 1.1 and <= 1.3 Bypass Authentication | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720178 | Rockwell Automation RSLinx Classic < 2.58 DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720194 | Siemens SIMATIC S7-1500 PLCs < 1.5 Random Number Generator Insufficient Entropy | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720197 | Siemens SIMATIC S7-1200 PLCs < 4.0 HTTP Packets DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720202 | Siemens SIMATIC S7-1500 PLCs < 1.5 HTTPS Packets DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720203 | Siemens TIA Portal 13 Arbitrary Code Execution | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720204 | Siemens TIA Portal 13 Arbitrary File Read | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720205 | Siemens SCALANCE X-200, XR300-WG 3.0 and 3.1 RCDP Triggered Unauthorized Administrative Actions | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720214 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Buffer Overflow Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720215 | Rockwell Automation Micrologix 1400 <= 21.2 Exploitable Access Control | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720217 | Rockwell Automation Micrologix 1400 <= 21.2 Memory Module Bit Exploit | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720218 | Rockwell Automation Micrologix 1400 <= 21.2 Read/Write Exploit | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720219 | Rockwell Automation Micrologix 1400 <= 21.2 Master Password Leak | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720229 | Rockwell Automation Stratix Ethernet Switches < 15.3 IOS DHCPOFFER Relay Reply DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720233 | Rockwell Automation Powermonitor1000 1408 Unauthorized Administrator Access | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720237 | Schneider Electric Magelis HMIs Built-in Web Server Multiple Open Connections DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720243 | Schneider Electric Modicon Multiple Controllers URL Redirection | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720244 | Schneider Electric Modicon Multiple Controllers Unauthorized Password Delete | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720267 | Siemens TIA Portal < 15.1 Update 5 Arbitrary Code Execution | Nessus Network Monitor | SCADA | 7/22/2019 | 9/30/2019 | high |
| 720272 | Schneider Electric Modicon Controllers (ICSA-19-136-01) | Nessus Network Monitor | SCADA | 7/26/2019 | 9/30/2019 | high |
| 720279 | Rockwell Automation Stratix Ethernet Switches < 15.3 IOS Resource Management Errors and Improper Input Validation | Nessus Network Monitor | SCADA | 8/18/2019 | 9/30/2019 | high |
| 720280 | Rockwell Automation Stratix Ethernet Switches < 15.3 IOS Uncontrolled Resource Consumption | Nessus Network Monitor | SCADA | 8/19/2019 | 9/30/2019 | high |
| 720285 | Yokogawa License Manager Service Input Validation Error (ICSA-19-029-01) | Nessus Network Monitor | SCADA | 8/28/2019 | 9/30/2019 | critical |
| 720287 | Rockwell Automation Stratix 8300 Ethernet Switches < 15.3 IOS Improper Input Validation and Resource Management Errors (ICSA-18-107-05) | Nessus Network Monitor | SCADA | 9/24/2019 | 9/30/2019 | critical |
| 720288 | Rockwell Automation Stratix Ethernet Switches < 15.3 IOS Improper Input Validation and Resource Management Errors (ICSA-18-107-04) | Nessus Network Monitor | SCADA | 9/24/2019 | 9/30/2019 | critical |