| 720025 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Improper Authentication | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720049 | Siemens SIMATIC S7-1200 2.x < 4.x Header Injection | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720052 | GE Multilink Swtiches Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720060 | Siemens RUGGEDCOM WIN Multiple Devices Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720075 | Schneider Electric Modicon M340 PLCs Buffer Overflow | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720100 | Rockwell Automation/Allen-Bradley MicroLogix 1400 Series B FRN < 21.2 Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720111 | Siemens Multiple Devices Profinet DCP Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720113 | Rockwell Automation ControlLogix 5580 and CompactLogix 5380 Resource Exhaustion (ICSA-17-094-05) | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720124 | Rockwell Automation/Allen-Bradley MicroLogix Controllers <= 16.00 Information Exposure | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720132 | Rockwell Automation/Allen-Bradley CompactLogix and Compact GuardLogix <= 30.014 Improper Input Validation (ICSA-18-172-02) | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720133 | ABB SREA-01 and SREA-50 Ethernet Adapters Path Traversal | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720136 | Siemens SCALANCE X Switches Improper Input Validation | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720137 | Yokogawa STARDOM Controllers <= R4.10 Hardcoded Credentials | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720141 | Rockwell Automation/Allen-Bradley Multiple Devices Authentication Bypass (ICSA-18-310-02) | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720144 | Siemens Multiple Products Improper Input Validation | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720149 | Schneider Electric Modicon Multiple Controllers Hardcoded Credentials | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720157 | Schneider Electric ETG3000 FactoryCast HMI Gateway <= 1.60 IR 04 Hardcoded Credentials | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720162 | Rockwell Automation RSLinx Classic <= 3.90.01 and FactoryTalk Linx Gateway <= 3.90.00 user privileges escalation | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720164 | Siemens SIMATIC ET 200SP 2.0 < 2.1.6 and SIMATIC S7-1500 2.0 < 2.5 DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720167 | Siemens SIMATIC HMI Panels < 15.4 Integrated Webserver HTTP Header Injection | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720169 | Siemens SCALANCE S602, S612, S623, S627-2M < 4.0.1.1 Cross-Site Scripting (XSS) | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720176 | Emerson Multiple RTUs Hardcoded Credentials Storage | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720180 | Rockwell Automation RSLinx Enterprise Irregular UDP Packet Size DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720181 | Rockwell Automation RSLinx Classic < 3.73 Arbitrary Code Execution | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720182 | Rockwell Automation RSLinx Classic <= 4.00.01 Malformed CIP Packet Termination (deprecated) | Nessus Network Monitor | SCADA | | | high |
| 720187 | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x ISO-TSAP Port DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720189 | Siemens SIMATIC S7-1500 PLCs < 1.5 Multiple Vulnerabilities | Nessus Network Monitor | SCADA | 5/8/2019 | 10/9/2019 | high |
| 720191 | Siemens SIMATIC S7-1500 PLCs < 1.5 Web Server Open Redirect | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720192 | Siemens SIMATIC S7-1500 < 1.5 and S7-1200 PLCs < 4.0 Cross Site Request Forgery | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720195 | Siemens SIMATIC S7-1200 PLCs < 4.0 PROFINET Packets DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720198 | Siemens SIMATIC S7-1500 PLCs < 1.5 Improper Resource Release DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720199 | Siemens SIMATIC S7-1200 PLCs < 4.0 ISO-TSAP Packets DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720208 | Rockwell Automation 1756-ENBT/A Web Server Internal Information Exposure | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720213 | Rockwell Automation RSLogix 5000 <= 21 .ACD File Password Protection Failure | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
| 720234 | Schneider Electric Quantum 140NOE771 Network Interface Module Arbitrary Firmware Updates Installation | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720236 | Schneider Electric Magelis XBT HMI Hardcoded Configuration Password | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720239 | Schneider Electric Modicon Multiple Controllers Authorization Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720241 | Schneider Electric Modicon Multiple Controllers Arbitrary Code Execution | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720246 | Schneider Electric Modicon Multiple Controllers Unverified Password Change | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
| 720247 | Schneider Electric Modicon Multiple Controllers Information Exposure | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
| 720255 | Aruba Instant Web and Siemens SCALANCE W1750D Command Injection | Nessus Network Monitor | SCADA | 6/4/2019 | 9/30/2019 | high |
| 720256 | Aruba Instant Web and Siemens SCALANCE W1750D Cross-Site Scripting | Nessus Network Monitor | SCADA | 6/4/2019 | 9/30/2019 | medium |
| 720266 | Rockwell Automation RSLinx Classic <= 4.00.01 Multiple Vulnerabilities (ICSA-18-263-02) | Nessus Network Monitor | SCADA | 7/15/2019 | 9/30/2019 | critical |
| 720268 | Crestron DGE-100 Continuous Name Change Denial of Service | Nessus Network Monitor | SCADA | 7/23/2019 | 9/30/2019 | high |
| 720281 | Rockwell Automation Stratix 5950 Industrial EtherNet/IP Security Appliance < 15.3 Improper Input Validation | Nessus Network Monitor | SCADA | 8/19/2019 | 9/30/2019 | high |
| 720291 | Rockwell Automation Stratix 5100 Wireless Access Point and Workgroup Bridge < 15.4 Reusing a Nonce (ICSA-17-299-02) | Nessus Network Monitor | SCADA | 9/5/2019 | 9/30/2019 | high |
| 7203 | Leaked DNS Query Detection - ISATAP Request (IPv6) | Nessus Network Monitor | Data Leakage | 5/26/2016 | 8/16/2018 | low |
| 720301 | Emerson DeltaV Smart Switch Multiple Vulnerabilities (ICSA-18-228-01) | Nessus Network Monitor | SCADA | 9/19/2019 | 9/30/2019 | high |
| 720302 | Siemens SIMATIC RF6XXR < 3.2.1 Multiple Vulnerabilities (ICSA-19-192-04) | Nessus Network Monitor | SCADA | 10/2/2019 | 10/2/2019 | medium |
| 720312 | Siemens Industrial Products Integer Overflow or Wraparound or Uncontrolled Resource Consumption (ICSA-19-253-03) | Nessus Network Monitor | SCADA | 11/3/2019 | 11/3/2019 | high |