Rockwellautomation Factorytalk Improper Restriction of Operations within the Bounds of a Memory Buffer

high Tenable.ot Plugin ID 500445
New! Plugin Severity Now Using CVSS v3

The calculated severity for Plugins has been updated to use CVSS v3 by default. Plugins that do not have a CVSS v3 score will fall back to CVSS v2 for calculating severity. Severity display preferences can be toggled in the settings dropdown.

Description

In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.

Solution

Refer to vendor advisory for Security Updates

See Also

https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944

https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05

Plugin Details

Severity: High

ID: 500445

Version: 1.0

Type: local

Family: SCADA

Published: 8/10/2021

Updated: 8/10/2021

Risk Information

CVSS Score Source: CVE-2020-12031

CVSS v2

Risk Factor: Medium

Base Score: 4.6

Vector: AV:L/AC:L/Au:N/C:P/I:P/A:P

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*

Patch Publication Date: 7/20/2020

Vulnerability Publication Date: 7/20/2020

Reference Information

CVE: CVE-2020-12031